Automated 2‐Dimensional Measurement of Vestibular Schwannoma: Validity and Accuracy of an Artificial Intelligence Algorithm

Author:

Neve Olaf M.1ORCID,Romeijn Stephan R.2ORCID,Chen Yunjie3ORCID,Nagtegaal Larissa12ORCID,Grootjans Willem2ORCID,Jansen Jeroen C.1ORCID,Staring Marius3ORCID,Verbist Berit M.2ORCID,Hensen Erik F.1ORCID

Affiliation:

1. Department of Otorhinolaryngology–Head and Neck Surgery Leiden University Medical Center Leiden The Netherlands

2. Department of Radiology Leiden University Medical Center Leiden The Netherlands

3. Department of Radiology, Division of Image Processing Leiden University Medical Center Leiden The Netherlands

Abstract

AbstractObjectiveValidation of automated 2‐dimensional (2D) diameter measurements of vestibular schwannomas on magnetic resonance imaging (MRI).Study DesignRetrospective validation study using 2 data sets containing MRIs of vestibular schwannoma patients.SettingUniversity Hospital in The Netherlands.MethodsTwo data sets were used, 1 containing 1 scan per patient (n = 134) and the other containing at least 3 consecutive MRIs of 51 patients, all with contrast‐enhanced T1 or high‐resolution T2 sequences. 2D measurements of the maximal extrameatal diameters in the axial plane were automatically derived from a 3D‐convolutional neural network compared to manual measurements by 2 human observers. Intra‐ and interobserver variabilities were calculated using the intraclass correlation coefficient (ICC), agreement on tumor progression using Cohen's kappa.ResultsThe human intra‐ and interobserver variability showed a high correlation (ICC: 0.98‐0.99) and limits of agreement of 1.7 to 2.1 mm. Comparing the automated to human measurements resulted in ICC of 0.98 (95% confidence interval [CI]: 0.974; 0.987) and 0.97 (95% CI: 0.968; 0.984), with limits of agreement of 2.2 and 2.1 mm for diameters parallel and perpendicular to the posterior side of the temporal bone, respectively. There was satisfactory agreement on tumor progression between automated measurements and human observers (Cohen's κ = 0.77), better than the agreement between the human observers (Cohen's κ = 0.74).ConclusionAutomated 2D diameter measurements and growth detection of vestibular schwannomas are at least as accurate as human 2D measurements. In clinical practice, measurements of the maximal extrameatal tumor (2D) diameters of vestibular schwannomas provide important complementary information to total tumor volume (3D) measurements. Combining both in an automated measurement algorithm facilitates clinical adoption.

Publisher

Wiley

Subject

Otorhinolaryngology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3