Dosimetric impact of the respiratory motion of the liver dome in stereotactic body radiotherapy for spine metastasis: A planning study

Author:

Okamoto Hiroyuki1ORCID,Nonaka Midori2,Chiba Takahito1ORCID,Kaneda Tomoya3,Kobayashi Yuta1,Nakamura Satoshi1,Nakayama Hiroki1,Iijima Kotaro14,Shuto Yasunori12,Yonemura Miki1,Oshika Riki1,Kishida Hironori1,Urago Yuka1,Nishitani Masato15,Nishina Shuka16,Sakamoto Takumi16,Shibata Yoshihiro2,Goka Tomonori2,Igaki Hiroshi3

Affiliation:

1. Radiation Safety and Quality Assurance Division National Cancer Center Hospital Tokyo Japan

2. Department of Radiological Technology National Cancer Center Hospital Tokyo Japan

3. Department of Radiation Oncology National Cancer Center Hospital Tokyo Japan

4. Department of Radiation Oncology Juntendo University Graduate School of Medicine Tokyo Japan

5. Department of Radiological Sciences Graduate School of Human Health Sciences Tokyo Metropolitan University Tokyo Japan

6. Department of Radiological Sciences Komazawa University Graduate School Tokyo Japan

Abstract

AbstractPurposeThis study aimed to clarify the dosimetric impact of the respiratory motion of the liver on stereotactic body radiation therapy (SBRT) for spine metastasis and examine the utility of introducing beam avoidance (beam‐off at specific gantry angles).MethodsA total of 112 consecutive patients who underwent SBRT for spine metastasis between 2018 and 2024 were examined. Overall, 15 patients who had lesions near the liver dome were included in this study. Retrospective treatment plans were generated using computed tomography (CT) images acquired during inhalation and exhalation to evaluate the dosimetric impact of respiratory motion of the liver. The dose difference (DD) and relative value (DD%) were evaluated using the dose‐volume histogram (DVH) metrics, planning target volume Dmax, D95%, spinal cord D0.035 cc, and esophagus D2.5 cc. The magnitude of the liver movements was evaluated based on differences of liver size Lave at the isocentric axial plane between the inspiratory and expiratory CT images.ResultsThe DD in almost all DVH metrics tended to increase when the liver moved away from the target during inhalation: For example, Mean a standard deviation (SD) DD in PTV D95% for the treatment plan incorporating beam avoidance and those without beam avoidance was 0.5 0.3 and 0.9 0.6 Gy, respectively. The spinal cord D0.035 cc for those shows 0.4 0.2 and 0.7 0.7 Gy, respectively. The treatment plans without beam avoidance also showed moderate or strong correlations between Lave and DD for almost all DVH metrics. No correlation was seen in the beam avoidance plan. The spinal cord D0.035 cc revealed approximately 1 Gy or +4% in DD when Lave was < −4 cm.ConclusionsRespiratory motion of the liver dome can cause substantial dosimetric discrepancies in the dose delivered to the spinal cord, although the extent depends on patient variables. Dose assessment should be performed for determining the appropriate means of respiratory management, such as breath‐hold. Alternatively, beam avoidance effectively mitigates the impact.