Investigating Transducer–Tissue Interface Pressure for Soft Tissue Stress–Strain Behavior and the Effects on Echoic Intensities in Ultrasound Imaging of Periodontium

Author:

La Thanh Giang1ORCID,Nguyen Kim Cuong T.12ORCID,Kaipatur Neelambar3,Lou Edmond H. M.4ORCID,Major Paul W.3ORCID,Le Lawrence H.1235ORCID

Affiliation:

1. Department of Radiology and Diagnostic Imaging University of Alberta Edmonton Alberta T6G 2R7 Canada

2. Department of Biomedical Engineering University of Alberta Edmonton Alberta T6G 2V2 Canada

3. School of Dentistry University of Alberta Edmonton Alberta T6G 1C9 Canada

4. Department of Electrical and Computer Engineering University of Alberta Edmonton Alberta T6G 1H9 Canada

5. Department of Physics University of Alberta Edmonton Alberta T6G 2E1 Canada

Abstract

AbstractDiagnostic ultrasound (US) is a major imaging modality to visualize soft tissues and blood flow with the advantages of real‐time imaging, high acceptability to patients, and absence of ionizing radiation. US imaging provides important clinical measurements, e.g., thickness of gingiva for treatment planning in orthodontics, periodontics, and implantology; or thickness of subcutaneous adipose for optimizing insulin injection. However, the image quality and measurements of anatomical structures can be inconsistent, i.e., due to varying pressure exerted by an US transducer. Herein, a simple device is developed to real‐time measure the interface pressure applied on tissues by the US transducer. A thin‐film piezo‐resistive sensor with a small footprint is integrated to sense the pressure. A theoretical model, based on hyperelastic material behavior, is verified using the pressure measured by the thin film sensor and the thickness determined on ultrasonograms. The device is also tested on porcine samples in the pressure range of 50–300 kPa for imaging gingiva boundaries, identifying tissue thickness, and probing tissue biomenchanical properties. The device enables the understanding on the optimal range of applied pressure for higher contrast imaging. The information of the on‐tissue pressure and the tissue deformation determined on the US images help to derive the biomechanical stress–strain behavior of the tissues.

Funder

University of Alberta

Natural Sciences and Engineering Research Council of Canada

Publisher

Wiley

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370