AbstractBackgroundThe recent trend toward 10 MV for volumetric radiotherapy treatment such as volumetric modulated arc therapy (VMAT), stereotactic radiosurgery (SRS), and stereotactic ablative body radiotherapy (SABR) introduces photoneutron production, with implications for non‐therapeutic patient dose and additional shielding requirements for treatment room design. The sharply nonlinear drop‐off in photoneutron production below 10 MV to negligible at 6 MV has scarcely been characterized quantitatively, yet can elucidate important practical insights.PurposeTo measure photoneutron yields in a medical linac at 8 MV, which may strike a reasonable balance between usefully increased beam penetration and dose rate as compared to 6 MV while reducing photoneutron production which is present at 10 MV.MethodsA Varian iX linear accelerator undergoing decommissioning at our clinic was made to operate over a range of photon energies between 6 and 15 MV by calibrating the bending magnet and adjusting other beam generation parameters. Neutron dose within the treatment room was measured using an Anderson‐Braun type detector over a continuum of intermediate energies.ResultsThe photoneutron production for energies below 10 MV was measured, adding to data that is otherwise scarce in the literature. Our results are consistent with previously published results for neutron yield. We found that the photoneutron production at 8 MV was about 1/10 of the value at 10 MV, and about 10 times higher than detector background at 6 MV.ConclusionsPhotoneutron production drops off below 10 MV, but is still present at 8 MV. An 8 MV beam is more penetrating than a 6 MV beam, and may offer a suitable tradeoff for modern radiotherapy techniques such as VMAT, SRS, and SABR. Further studies are needed to better understand the impact on treatment plan quality between 8 and 10 MV beams considering the benefits to facility requirements and non‐therapeutic patient dose.

Publisher

Wiley

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3