AbstractSteel plate girders with I‐section are frequently used in industrial buildings and bridge design as prismatic members that means as members with parallel flanges and rectangular webs. The structural efficiency can significantly be achieved if such members are designed with tapered webs that means with non‐rectangular webs. Depending on the flange inclination and the moment diagram, the stress in the webs of tapered plate girders is significantly affected also as known as Résal effect. Furthermore, the structural efficiency of plate girders can be improved if the flat webs are replaced by corrugated webs. The gain in out‐of‐plane stiffness due to the corrugated webs reduces the buckling sensitivity of the web. As tapered plate girders with sinusoidally corrugated webs under shear forces have not been subject of research up to now, a numerical investigation on the shear force resistance of such girders has been made. The most important findings are presented. It can be stated that the shear force resistance of tapered girders with corrugated webs cannot accurately be predicted by the existing calculation models for prismatic members.
Subject
General Earth and Planetary Sciences,General Environmental Science
Reference17 articles.
1. Tapered plate girders under shear: Tests and numerical research
2. EN 1993‐1‐5(2006).Eurocode 3 – Design of steel structures – Part 1‐5: Plated structural elements.CEN Brussels.
3. Zum Tragverhalten von Wellstegträgern;Pasternak H.;Bauingenieur,1998
4. Shear strength and design of trapezoidally corrugated steel webs
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献