Efficacy and safety of the Aria pulmonary endovascular device in pulmonary hypertension

Author:

Gerges Christian1ORCID,Vollmers Karl2,Skoro‐Sajer Nika1,Dannenberg Varius1,Hartig Valerie1,Pritzker Marc R.3,Scandurra John2,Weir E. Kenneth3,Lang Irene M.1

Affiliation:

1. Division of Cardiology, Department of Internal Medicine II Vienna General Hospital, Medical University of Vienna Vienna Austria

2. Aria CV Saint Paul MN USA

3. University of Minnesota Medical School Minneapolis MN USA

Abstract

ABSTRACTAimsA common feature of various forms of pulmonary hypertension (PH) is progressive decline of pulmonary arterial compliance (CPA), which correlates with reduced survival. In this acute study, we evaluated feasibility, safety and haemodynamic performance of the Aria pulmonary endovascular device in patients with PH associated with left heart disease (PH‐LHD) and chronic lung disease (PH‐CLD).Methods and resultsEight patients with PH‐LHD and 10 patients with PH‐CLD were included in this study. The device was placed in the main pulmonary artery via the right femoral vein and was connected by a catheter to a gas‐filled reservoir outside the body. During systole, gas shifts from the balloon to the reservoir, leading to deflation of the balloon. In diastole, the gas returns from the reservoir to the balloon, leading to balloon inflation and enhancing diastolic blood flow to the distal pulmonary capillary bed. Haemodynamics were assessed at baseline, and again with device off, device on and device off. The primary safety endpoint was the incidence of serious adverse events through 30 days after the procedure. No complications or investigational device‐related serious adverse events occurred. Device activation in PH‐LHD and PH‐CLD patients decreased pulmonary arterial pulse pressure by 5.6 ± 4.2 mmHg (−12%; p = 0.003) and 4.2 ± 2.2 mmHg (−11%; p < 0.001), increased CPA by 0.4 ± 0.2 ml/mmHg (+23%; p = 0.004) and 0.4 ± 0.3 ml/mmHg (+25%; p = 0.001), and increased right ventricular‐to‐pulmonary vascular (RV‐PV) coupling by 0.24 ± 0.18 (+40%; p = 0.012) and 0.11 ± 0.07 (+21%; p = 0.001), respectively.ConclusionsTemporary implantation of the Aria endovascular device was feasible and safe. Device activation resulted in acute improvement of CPA and RV‐PV coupling.

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3