Control of a sulfadoxine/trimethoprim combination in the competition horse: Elimination, metabolism and detection following an intravenous administration

Author:

Schenk Ina1ORCID,Broussou Diane2,Roques Beatrice2ORCID,Lagershausen Henrike3,Machnik Marc1,Röttgen Helma1,Toutain Pierre‐Louis24ORCID,Thevis Mario1ORCID

Affiliation:

1. Institute of Biochemistry, Center for Preventive Doping Research German Sport University Cologne Cologne Germany

2. INTHERES Université de Toulouse, INRAE, ENVT Toulouse France

3. German Equestrian Federation Warendorf Germany

4. Comparative Biomedical Sciences, The Royal Veterinary College University of London London UK

Abstract

AbstractThe combination of sulfadoxine (SDO) with trimethoprim (TMP) is widely used in veterinarian medicine. The aim of the present study was to compare excretion profiles and detection time windows of SDO and TMP in plasma and urine by means of a validated quantitative method.Eight horses received a single intravenous (i.v.) dose of 2.7 mg TMP and 13.4 mg SDO per kg bodyweight. Plasma and urine samples were collected up to 15 and 70 days post‐administration, respectively.While urine samples underwent an enzymatic hydrolysis, plasma samples were proteolysed before further analysis. After solid‐phase extraction, samples were analysed by liquid chromatography/electrospray ionisation tandem mass spectrometry in positive ionisation mode. The applied multiple reaction monitoring (MRM) method allowed the detection of SDO and TMP with a lower limit of detection of 0.03 ng/mL in plasma and 0.2 (SDO) and 0.4 ng/mL (TMP) in urine, respectively. In the present study, detection times for SDO were 15 days in plasma and 49 days in urine, respectively. TMP was detected for up to 7 days in plasma and up to 50 days in urine, respectively. The detection via the TMP metabolite 3‐desmethyl‐trimethoprim was possible for 70 days in urine. Detection times of the other confirmed metabolites N4‐acetylated sulfadoxine, hydroxytrimethoprim, trimethoprim‐1‐oxide and trimethoprim‐3‐oxide were significantly lower.In order to postulate reasonable screening limits (SLs) to control specific withdrawal times, a Monte Carlo simulation was performed for SDO. The proposed SL of 10 ng/mL SDO in blood and 300 ng/mL urine corresponds to a detection time of 4 days.

Publisher

Wiley

Subject

Spectroscopy,Pharmaceutical Science,Environmental Chemistry,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3