Experimental and Monte Carlo‐based determination of magnetic field correction factors kB,Q$k_{B,Q}$ in high‐energy photon fields for two ionization chambers

Author:

Alissa Mohamad12,Zink Klemens123,Kapsch Ralf‐Peter4,Schoenfeld Andreas A.5,Frick Stephan4,Czarnecki Damian1

Affiliation:

1. Institute for Medical Physics and Radiation Protection University of Applied Sciences Giessen Giessen Germany

2. Department of Radiotherapy and Radiation Oncology University Medical Center Giessen and Marburg Marburg Germany

3. Marburg Ionbeam Therapy Center (MIT) Marburg Germany

4. German National Metrology Institute (PTB) Braunschweig Germany

5. Sun Nuclear A Mirion Medical Company Melbourne Florida USA

Abstract

AbstractBackgroundThe integration of magnetic resonance tomography into clinical linear accelerators provides high‐contrast, real‐time imaging during treatment and facilitates online‐adaptive workflows in radiation therapy treatments. The associated magnetic field also bends the trajectories of charged particles via the Lorentz force, which may alter the dose distribution in a patient or a phantom and affects the dose response of dosimetry detectors.PurposeTo perform an experimental and Monte Carlo‐based determination of correction factors , which correct the response of ion chambers in the presence of external magnetic fields in high‐energy photon fields.MethodsThe response variation of two different types of ion chambers (Sun Nuclear SNC125c and SNC600c) in strong external magnetic fields was investigated experimentally and by Monte Carlo simulations. The experimental data were acquired at the German National Metrology Institute, PTB, using a clinical linear accelerator with a nominal photon energy of 6 MV and an external electromagnet capable of generating magnetic flux densities of up to 1.5 T in opposite directions. The Monte Carlo simulation geometries corresponded to the experimental setup and additionally to the reference conditions of IAEA TRS‐398. For the latter, the Monte Carlo simulations were performed with two different photon spectra: the 6 MV spectrum of the linear accelerator used for the experimental data acquisition and a 7 MV spectrum of a commercial MRI‐linear accelerator. In each simulation geometry, three different orientations of the external magnetic field, the beam direction and the chamber orientation were investigated.ResultsGood agreement was achieved between Monte Carlo simulations and measurements with the SNC125c and SNC600c ionization chambers, with a mean deviation of 0.3% and 0.6%, respectively. The magnitude of the correction factor strongly depends on the chamber volume and on the orientation of the chamber axis relative to the external magnetic field and the beam directions. It is greater for the SNC600c chamber with a volume of 0.6 cm3 than for the SNC125c chamber with a volume of 0.1 cm3. When the magnetic field direction and the chamber axis coincide, and they are perpendicular to the beam direction, the ion chambers exhibit a calculated overresponse of less than 0.7(6)% (SNC600c) and 0.3(4)% (SNC125c) at 1.5 T and less than 0.3(0)% (SNC600c) and 0.1(3)% (SNC125c) for 0.35 T for nominal beam energies of 6 MV and 7 MV. This chamber orientation should be preferred, as may increase significantly in other chamber orientations. Due to the special geometry of the guard ring, no dead‐volume effects have been observed in any orientation studied. The results show an intra‐type variation of 0.17% and 0.07% standard uncertainty (k=1) for the SNC125c and SNC600c, respectively.ConclusionMagnetic field correction factors for two different ion chambers and for typical clinical photon beam qualities were presented and compared with the few data existing in the literature. The correction factors may be applied in clinical reference dosimetry for existing MRI‐linear accelerators.

Publisher

Wiley

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3