High‐performance 110 kVp hard x‐ray detector based on all‐crystalline‐surface passivated perovskite single crystals

Author:

Ko Juyoung1,Park Beomjun12,Byun Jangwon1,Pandey Sandeep12,Jo Ajin3,Lee Joo‐Hong45,Lee Wonho6,Lee Jin‐Wook45,Park Nam‐Gyu57,Lee Man‐Jong12ORCID

Affiliation:

1. Department of Chemistry Konkuk University Seoul Republic of Korea

2. Advanced Crystal Material/Device Research Center Konkuk University Seoul Republic of Korea

3. Health Science Research Center Korea University Seoul Republic of Korea

4. Department of Nano Engineering and Department of Nano Science and Technology SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University Suwon Republic of Korea

5. SKKU Institute of Energy Science & Technology (SIEST) Sungkyunkwan University Suwon Republic of Korea

6. Department of Health and Environmental Science Korea University Seoul Republic of Korea

7. School of Chemical Engineering, Center for Antibonding Regulated Crystals Sungkyunkwan University Suwon Republic of Korea

Abstract

AbstractHalide perovskite single crystals (SCs) have attracted much attention for their application in high‐performance x‐ray detectors owing to their desirable properties, including low defect density, high mobility–lifetime product (μτ), and long carrier diffusion length. However, suppressing the inherent defects in perovskites and overcoming the ion migration primarily caused by these defects remains a challenge. This study proposes a facile process for dipping Cs0.05FA0.9MA0.05PbI3 SCs synthesized by a solution‐based inverse temperature crystallization method into a 2‐phenylethylammonium iodide (PEAI) solution to reduce the number of defects, inhibit ion migration, and increase x‐ray sensitivity. Compared to conventional spin coating, this simple dipping process forms a two‐dimensional PEA2PbI4 layer on all SC surfaces without further treatment, effectively passivating all surfaces of the inherently defective SCs and minimizing ion migration. As a result, the PEAI‐treated perovskite SC‐based x‐ray detector achieves a record x‐ray sensitivity of 1.3 × 105 μC Gyair−1 cm−2 with a bias voltage of 30 V at realistic clinical dose rates of 1–5 mGy s−1 (peak potential of 110 kVp), which is 6 times more sensitive than an untreated SC‐based detector and 3 orders of magnitude more sensitive than a commercial α‐Se‐based detector. Furthermore, the PEAI‐treated‐perovskite SC‐based x‐ray detector exhibits a low detection limit (73 nGy s−1), improved x‐ray response, and clear x‐ray images by a scanning method, highlighting the effectiveness of the PEAI dipping approach for fabricating next‐generation x‐ray detectors.image

Funder

Agency for Defense Development

Defense Acquisition Program Administration

Korea Institute of Energy Technology Evaluation and Planning

Publisher

Wiley

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3