A mathematical model for velocity‐selective arterial spin labeling

Author:

Liu Thomas T.123ORCID,Wong Eric C.123,Bolar Divya S.12,Chen Conan124,Barnes Ryan S.124

Affiliation:

1. Center for Functional MRI University of California San Diego La Jolla California USA

2. Department of Radiology University of California San Diego La Jolla California USA

3. Department of Psychiatry University of California San Diego La Jolla California USA

4. Department of Electrical and Computer Engineering University of California San Diego La Jolla California USA

Abstract

AbstractPurposeTo present a theoretical framework that rigorously defines and analyzes key concepts and quantities for velocity selective arterial spin labeling (VSASL).Theory and MethodsAn expression for the VSASL arterial delivery function is derived based on (1) labeling and saturation profiles as a function of velocity and (2) physiologically plausible approximations of changes in acceleration and velocity across the vascular system. The dependence of labeling efficiency on the amplitude and effective bolus width of the arterial delivery function is defined. Factors that affect the effective bolus width are examined, and timing requirements to minimize quantitation errors are derived.ResultsThe model predicts that a flow‐dependent negative bias in the effective bolus width can occur when velocity selective inversion (VSI) is used for the labeling module and velocity selective saturation (VSS) is used for the vascular crushing module. The bias can be minimized by choosing a nominal labeling cutoff velocity that is lower than the nominal cutoff velocity of the vascular crushing module.ConclusionThe elements of the model are specified in a general fashion such that future advances can be readily integrated. The model can facilitate further efforts to understand and characterize the performance of VSASL and provide critical theoretical insights that can be used to design future experiments and develop novel VSASL approaches.

Publisher

Wiley

Reference29 articles.

1. Velocity-selective arterial spin labeling

2. Velocity-selective-inversion prepared arterial spin labeling

3. Velocity‐selective arterial spin labeling perfusion MRI: A review of the state of the art and recommendations for clinical implementation

4. LiuTT WongEC BolarDS ChenC BarnesRA.A mathematical model for velocity‐selective arterial spin labeling. Abstract presented at: 32nd Annual Scientific Meeting of the ISMRM.2023; Toronto Canada:2756.

5. Comparison of velocity‐selective arterial spin labeling schemes

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3