Characterization of GafchromicTM EBT4 film with clinical kV/MV photons and MeV electrons

Author:

Guan Fada1ORCID,Chen Huixiao1,Draeger Emily1,Li Yuting2,Aydin Resat3,Tien Christopher J.1,Chen Zhe1

Affiliation:

1. Department of Therapeutic Radiology Yale University School of Medicine New Haven Connecticut USA

2. Department of Radiation Physics The University of Texas MD Anderson Cancer Center, 1515 Holcombe Boulevard Houston Texas USA

3. Ashland Specialty Ingredients G.P. Bridgewater New Jersey USA

Abstract

AbstractObjectiveA newly developed GafchromicTM EBT4 film model was released recently. According to the vendor‐stated specifications, this new model maintains major features of its more recent predecessor, EBT3, but has a great improvement in the signal‐to‐noise ratio (SNR). The purpose of this study was to fully characterize the EBT4 model by testing its dose response dependence on beam energy using clinical photon and electron beams and validating its improvement in SNR.MethodsIn the beam energy dependence experiments, 6 MV and 15 MV photon beams, 6 MeV, 12 MeV and 20 MeV electron beams, 120 kVp and two 250 kVp x‐ray beams (with different half‐layer values) were selected, representing different clinical beam energies and radiation types. In the noise and SNR analyses, only the 6 MV photon beam was selected as the representative to compare between EBT4 and EBT3 models.ResultsThe energy dependence test results showed that there was a slight difference (<2% at most dose levels) in the dose response among the clinical MV photons and MeV electrons. However, a large deviation (>10%) in the dose response was found for the 120 kVp x‐ray beam. For the two 250 kVp x‐ray beams, the difference in the dose response was moderate (<5%), but not negligible. The noise and SNR results showed a reduced noise and strengthened SNR in EBT4.ConclusionWe conclude that the EBT4 film has a minimal energy dependence for MV photon and MeV electron beams but has a notable energy dependence for kilovoltage x‐ray beams, and the vendor‐stated features of the reduced noise and improved SNR in EBT4 are validated.

Publisher

Wiley

Subject

Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3