Field‐representative evaluation of PID‐polarization in TOPCon PV modules by accelerated stress testing

Author:

Hacke Peter1ORCID,Spataru Sergiu2ORCID,Habersberger Brian3ORCID,Chen Yifeng4ORCID

Affiliation:

1. National Renewable Energy Laboratory 15013 Denver West Parkway Golden Colorado 80401 USA

2. Department of Electrical and Photonics Engineering Technical University of Denmark (DTU) Roskilde 4000 Denmark

3. Dow Inc. 230 Abner Jackson Pkwy Lake Jackson Texas 77566 USA

4. Trina Solar Co., Ltd No. 2 Tianhe Road, Trina PV Industrial Park, Xinbei District Changzhou Jiangsu China

Abstract

AbstractPotential‐induced degradation‐polarization (PID‐p) can reduce module power, but how to project the extent to which PID‐p may occur in field conditions considering the factors of system voltage, condensed moisture, temperature, and illumination has not been clarified. Using tunnel oxide passivated contact (TOPCon) modules, this work demonstrates a method to test full‐size crystalline silicon PV modules for PID‐p to provide field‐representative results. In initial screening tests with positive or negative 1000 V electrical bias applied at 60°C for 96 h using Al foil electrodes on the glass surfaces, the module type exhibited reversible PID‐p only on the front face when the cell circuit was in negative voltage potential. No PID was detected on the rear after testing in either polarity. We then evaluated the PID‐p sensitivity on the front side under different UV irradiances while maintaining the glass surface wet to estimate real‐world susceptibility to PID‐p. The magnitude of the observed behavior was fit using a previously developed charge transfer and depletion by light model. Whereas power loss with −1000 V applied to the cell circuit at 60°C for 96 h in the dark was about 30%, testing the module front under 0.051 W·m−2 nm−1 at 340 nm UVA irradiation using fluorescent tubes, the mean degradation was only 3%. When the modules were tested in the dark for PID‐p with in situ dark current–voltage (I‐V) characterization, the thermal activation energy for degradation was 0.71 eV; for recovery in the dark, it was 0.58 eV. Whereas recovery from the degraded state at 60°C in the dark without voltage bias was 5% absolute in 38 h, rapid recovery of about 5% absolute was observed with 1000 W·s/m2 exposure at 25°C using a flash tester.

Funder

U.S. Department of Energy

Publisher

Wiley

Reference35 articles.

1. Potential-induced degradation in photovoltaic modules: a critical review

2. Potential‐Induced Degradation in High‐Efficiency n‐Type Crystalline‐Silicon Photovoltaic Modules: A Literature Review

3. Review of Potential‐Induced Degradation in Bifacial Photovoltaic Modules

4. SwansonR CudzinovicM DeCeusterDet al.The surface polarization effect in high‐efficiency silicon solar cells. In 15th PVSEC 2005; Shanghai China;2005.

5. SwansonRM De CeusterD DesaiVet al.Preventing harmful polarization of solar cells. US Patent.2009.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3