Author:
Duan Rong-Xing,He Jie-Jun,Feng Tao,Huang Shu-Juan,Chen Li
Abstract
Owing to expensive cost and restricted structure, limited sensors are allowed to install in modern systems to monitor the working state, which can improve their availability. Therefore, an effective sensor placement method is presented based on a VIKOR algorithm considering common cause failure (CCF) under epistemic uncertainty in this paper. Specifically, a dynamic fault tree (DFT) is developed to build a fault model to simulate dynamic fault behaviors and some reliability indices are calculated using a dynamic evidence network (DEN). Furthermore, a VIKOR method is proposed to choose the possible sensor locations based on these indices. Besides, a sensor model is introduced by using a priority AND gate (PAND) to describe the failure sequence between a sensor and a component. All placement schemes can be enumerated when the number of sensors is given, and the largest system reliability is the best alternative among the placement schemes. Finally, a case study shows that CCF has some influence on sensor placement and cannot be neglected in the reliabilitybased sensor placement.
Publisher
Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne
Subject
Industrial and Manufacturing Engineering,Safety, Risk, Reliability and Quality
Reference44 articles.
1. 1. Acuña-Soto CM, Liern V, Pérez-Gladish B. A VIKOR-based approach for the ranking of mathematical instructional videos. Management Decision 2019; 57(2): 501-522, https://doi.org/10.1108/md-03-2018-0242.
2. 2. Assaf T, Dugan JB. Diagnosis based on reliability analysis using monitors and sensors. Reliability Engineering & System Safety 2008; 93(4): 509-521, https://doi.org/ 10.1016/j.ress.2006.10.024.
3. 3. Błachowski B, Świercz A, Ostrowski M, Tauzowski P, Olaszek P, Jankowski Ł. Convex relaxation for efficient sensor layout optimization in large‐scale structures subjected to moving loads. Computer-Aided Civil and Infrastructure Engineering 2020; 35(10): 1085-1100, https://doi.org/10.1111/mice.12553.
4. 4. Chow HM, Lam HF, Yin T, Au SK. Optimal sensor configuration of a typical transmission tower for the purpose of structural model updating. Structural Control and Health Monitoring 2011; 18(3): 305-320, https://doi.org/10.1002/stc.372.
5. 5. Dai G B, Ji G Y. Structure of Large Ground Modal Test Node Selecting and Optimizing Method Research. Journal of Vibration, Measurement & Diagnosis 2017; 37(05): 984-989, https://doi.org/j.cnki.issn.1004-6801.2017.05.020.
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献