Effect of Implant Angulation on the Rotational Displacement of a 3-Unit Bridge after Digital Impression

Author:

Arshad Mahnaz12ORCID,Asgari Amirmohsen3ORCID,Kharazifard Mohamad Javad4ORCID,Ameri Narges12ORCID

Affiliation:

1. Dental Research Center, Dentistry Research Institute, Tehran University of Medical Sciences, Tehran, Po. Code: 14399-55991, Iran

2. Department of Prosthodontics, School of Dentistry, International Campus, Tehran University of Medical Sciences, Tehran, Po. Code:14399-55991, Iran

3. Private Practice, Tehran, Iran

4. Department of Epidemiology and Biostatistics, Faculty of Public Health, Dental School, Tehran University of Medical Sciences, Tehran, Po. Code:14399-55991, Iran

Abstract

Objectives. This study aimed to assess the effect of implant angulation on the rotational displacement of a 3-unit bridge following a digital impression. Materials and Methods. This in vitro experimental study evaluated 3 master models of the maxilla with Kennedy’s class III partial edentulism and bilateral three-unit implant-supported fixed partial dentures. Two implants were placed with 0° (first model), 15° (second model), and 30° (third model) interimplant angles. The implants were placed bilaterally at the sites of first premolars and first molars from the posterior towards the anterior region and coded A (posterior) and B (anterior) in the left, and C (posterior) and D (anterior) in the right side. Next, their position was recorded using a coordinate measuring machine to serve as a reference. The models were then scanned by both 3Shape and Sirona digital scanners (12 times by each scanner). The obtained data were compared with the reference data three-dimensionally using GOM Inspect software to determine the rotational displacement of the implants. Data were analyzed by repeated-measures ANOVA, one-way ANOVA, paired sample t-test, and independent sample t-test ( P  < 0.05). Results. Since repeated-measures ANOVA showed that the interaction effect was significant ( P  = 0.010), the data were analyzed by subgroup analysis. The 3Shape scanner showed significantly higher accuracy for C-D region in model 2 ( P  = 0.001), and A-B region in model 1 ( P  ≤ 0.01). In the use of the 3Shape scanner, model 3 showed a lower error rate in the A-B region, compared with models 1 and 2. Model 1 showed higher error rate than models 2 and 3 in the C-D region ( P  ≤ 0.01). In the use of the Sirona scanner, model 1 showed a higher error rate than models 2 ( P  = 0.031) and 3 ( P  = 0.004) in the C-D region. Conclusion. In digital impressions of angulated implants in 3-unit bridges by using 3Shape and Sirona scanners, the rotational error decreases as the interimplant angle increases.

Publisher

Hindawi Limited

Subject

General Dentistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3