Evaluation of Hematocrit in Adults with Dengue by a Laboratory Information System

Author:

Sahassananda Duangjai1ORCID,Thanachartwet Vipa2ORCID,Chonsawat Putza3,Wongphan Benjamaporn3,Chamnanchanunt Supat2,Surabotsophon Manoon4,Desakorn Varunee2

Affiliation:

1. Information Technology Unit, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand

2. Department of Clinical Tropical Medicine, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand

3. Center Diagnostic Laboratory, Hospital for Tropical Diseases, Faculty of Tropical Medicine, Mahidol University, Bangkok 10400, Thailand

4. Pulmonary and Critical Care Division, Department of Medicine, Ramkhamhaeng Hospital, Bangkok 10240, Thailand

Abstract

The implementation of a laboratory information system (LIS) at the Hospital for Tropical Diseases in Thailand provides valuable medical resources, particularly for dengue. Hematocrit (Hct), which is often derived from hemoglobin (Hgb), is important in the diagnosis and management of dengue. This study aimed to evaluate the Hct value obtained from the LIS automated analyzer. We prospectively enrolled 163 hospitalized adults with dengue, for whom 1,141 real-time complete blood count (CBC) results were obtained via a hematology analyzer and updated in the LIS database. The median (interquartile range (IQR)) duration of analytic turnaround times (TATs) was 40.0 (30.0–53.0) minutes. Linear regression analysis indicated a significant relationship between Hgb and Hct with a coefficient of determination (Pearson’s R2) of 0.92 at red blood cell distribution width (RDW) ≤18, but Pearson’s R2 decreased to 0.78 at RDW >18. The Hct calculated from the three-fold conversion method and from the analyzer had a Pearson’s R2 of 0.92. At Hgb <12 g/dl and ≥16 g/dl, a greater difference between the two Hct values was observed, with median (IQR) differences of −0.8% (−1.9%–0.2%) and 0.8% (−0.1%–1.7%), respectively ( P value <0.05). In conclusion, the Hgb and Hct of patients with dengue were highly correlated at RDW ≤18. The Hct calculated from the three-fold conversion method and from the analyzer had an excellent relationship, except when the Hgb was <12 g/dl or ≥16 g/dl. Apart from routine CBC evaluation, the LIS could help for accurate data collection in clinical research and development.

Funder

Faculty of Tropical Medicine, Mahidol University

Publisher

Hindawi Limited

Subject

General Medicine,Microbiology,Parasitology

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3