Shaping Ability of XP Endo Shaper File in Curved Root Canal Models

Author:

Alfadley Abdulmohsen12ORCID,Alrajhi Abdalrhman1,Alissa Hamad1,Alzeghaibi Faisal1,Hamadah Lubna1,Alfouzan Khalid12,Jamleh Ahmed12ORCID

Affiliation:

1. Restorative and Prosthetic Dental Sciences, College of Dentistry, King Saud Bin Abdulaziz University for Health Sciences, National Guard Health Affairs, Riyadh, Saudi Arabia

2. King Abdullah International Medical Research Centre, National Guard Health Affairs, Riyadh, Saudi Arabia

Abstract

The aim of this study was to assess the shaping ability of the XP Shaper (XPS) file in severely curved canal models under simulated body temperature and compare it with that of the WaveOne Gold (WOG) file. Ninety-six simulated root canals were equally distributed into XPS and WOG systems to be shaped by eight files each. Files were assessed under a stereomicroscope prior to canal shaping to detect deformation if any. The canals were shaped at 35 ± 1°C using the X-Smart Plus motor. Images of the canals were obtained before and after instrumentation using a stereomicroscope to measure the amount of removed resin from both the inner and outer curvature sides at apex (0 mm) and 3 mm and 6 mm from the apex. The shaping time was calculated. The data were statistically analyzed by the independent t-test at 5% significance level. The XPS and WOG systems shaped the canals in 37.0 ± 9.5 and 62.6 ± 11.3 seconds (P<0.05), respectively. At the apex level, the amount of resin removal in both sides did not show a significant difference between the tested groups (P>0.05). At 3 mm and 6 mm levels, the WOG removed more resin than XPS at both sides (P<0.05). In XPS, deformation was observed in four files: one file after the first use, one file after the fourth use, and two files after the sixth use. In WOG, two files were deformed: one file after the fifth use and one file after the sixth use. One XPS file was fractured after the sixth use. In short, XPS and WOG files can be used in shaping severely curved canals as they showed the ability to maintain the original shape with minimal transportation. Both file systems showed signs of deformation after use with a lower number of deformed files observed in WOG throughout the experiment.

Funder

King Abdullah International Medical Research Center

Publisher

Hindawi Limited

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3