Electrooxidation and Development of a Highly Sensitive Electrochemical Probe for Trace Determination of the Steroid 11-Desoxycorticosterone Drug Residues in Water

Author:

Alsaggaf Wejdan T.1,El-Shahawi Mohammad S.1ORCID

Affiliation:

1. Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, Jeddah 21589, Saudi Arabia

Abstract

Anabolic-androgenic steroids (AASs), a class of compounds frequently misused by competitors and unfortunately by the general population, have lately attracted international attention. Thus, extraordinary demands for developing low cost, precise, rapid, and facile protocols for detection and/or determination of AAS have arisen. Hence, the current strategy explores for the first time the redox features of 21-hydroxypregn-4-ene-3, 20-dione, namely, 11-desoxycorticosterone (DCS) AA drug steroid at a glassy-carbon electrode (GCE) in a wide pH range (pH 2.0–10.0) by adsorptive differential pulse-anodic stripping voltammetry (DP- ASV) and cyclic voltammetry (CV). At pH 2, DP-ASV and CV at the optimized pH 2–3 displayed an irreversible anodic peak at 0.4 V versus Ag/AgCl electrode. The dependency of the anodic peak current of the CV at 0.4 V at various concentrations and scan rate of the DCS drug was characteristic of an electrode-coupled electron transfer of EE type mechanism. At the optimized parameters, the proposed strategy allowed quantification of DCS in the concentration range 2.5 -13.19 nM (0.83-4.36 ng mL−1) with satisfactory limits of detection (LOD) and quantization (LOQ) of 9.3 × 10−1 nM (3.1 × 10−1 ng mL−1) and 3.1 nM (1.02 ng mL−1), respectively. A relative standard deviation (RSD) of ±3.93% (n = 5) at 4.0 ng mL−1 DCS was achieved. The established probe was fruitfully employed and validated for trace determination of DCS residues in environmental water. The interference of several common diverse species on DCS sensing was insignificant revealing good selectivity. The established probe exhibited good sensitivity, selectivity, precision, and accuracy, short analytical time, and low cost compared with the reported methods, for DCS determination.

Funder

King Abdulaziz University

Publisher

Hindawi Limited

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3