The Application Value of Spiral CT Lung Densitometry Software in the Diagnosis of Radiation-Induced Lung Injury

Author:

Tao Qingsong1ORCID,Zhu Ting1ORCID,Ge Xiaoqin1ORCID,Gong Shengping1ORCID,Guo Jianxin1ORCID

Affiliation:

1. The Chemoradiotherapy Center, Ningbo No. 1 Hospital, Ningbo, Zhejiang 315000, China

Abstract

In order to study the application value of spiral CT lung density measurement software in the diagnosis of radioactive lung injury, the average CT values of lung apex, hilum, and diaphragm were measured by Pulmo automatic evaluation software of 16-slice spiral CT in 96 patients with different types of radiation lung injury diagnosed by conventional CT and 80 healthy subjects. The radiation lung injury on CT slices was classified, and the lung density was measured. In 96 patients with different types of radiation lung injury, 56 patients had different degrees of increase in average lung density, which was most obvious in the type of air insufficiency and chronic fibrosis. CT values of lung density in the ground glass stage and patch stage of acute radiation pneumonia had little influence due to the range and time of exposure. The lung density of 35 patients with radiation injury was measured in the normal range. There was a significant difference between normal lung density and abnormal lung density in different types of radiation lung injury (X2 = 56.718, P < 0.001 ). The mean lung density of 68 cases was normal and that of 12 cases was abnormal. There was a significant difference in lung density between the lung injury group and the normal group (X2 = 18.027, P < 0.001 ). Spiral CT lung density measurement can accurately evaluate the lung density values of different types of radiation lung injury and judge the correlation between lung density and different types of radiation lung injury. It is of great value to diagnose, locate, and master the radiation dose of different types of radiation lung injury.

Funder

Zhejiang Medical and Health Science-Technology Plan Project

Publisher

Hindawi Limited

Subject

Radiology, Nuclear Medicine and imaging

Reference20 articles.

1. Dual-energy CT in the diagnosis of occult acute scaphoid injury: a direct comparison with MRI

2. Injuries can be prevented in contact flag football!

3. CERN to produce radioisotopes for health;B. Leo;CERN Courier,2016

4. Application value of CT spectrum curve and iodine measurement in the early diagnosis of gastric cancer;W. Fang;Zhonghua Wei Chang Wai Ke Za Zhi,2015

5. The application of radioactive iodine in the diagnosis of thyroid disease;B. Skanse;Recueil des Travaux Chimiques des Pays-Bas,2015

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Possibilities of densitometry in the assessment of diffuse changes in the lung parenchyma;The Siberian Journal of Clinical and Experimental Medicine;2023-10-10