Elucidating the Capabilities of Mirrorless Large Core Bundled Plastic Fiber Optic Displacement Sensor for Paracetamol Detection

Author:

Zulkifli Mohd Zamani1ORCID,Azri Muhammad Fadhli Mohd1ORCID,Yusof Muhammad Khudhori Mohd1ORCID,Shafiee Saiful Arifin2ORCID,Sabere Awis Sukarni Mohmad3ORCID,Yao Lau Kuen4ORCID,Samsudin Sani Amril5ORCID,Bahari Muhammad Syahril6ORCID,Yasin Moh7ORCID

Affiliation:

1. Department of Physics, Kulliyyah of Science, International Islamic University Malaysia, Bandar Indera Mahkota, 25200 Kuantan, Pahang, Malaysia

2. Department of Chemistry, Kulliyyah of Science, International Islamic University Malaysia, Bandar Indera Mahkota, 25200 Kuantan, Pahang, Malaysia

3. Department of Pharmaceutical Chemistry, Kulliyyah of Pharmacy, International Islamic University Malaysia, Bandar Indera Mahkota, 25200 Kuantan, Pahang, Malaysia

4. Department of Electronics and Nanoengineering, Tietotie 3, Aalto University, 02150 Espoo, Finland

5. School of Chemical and Energy Engineering, Faculty of Engineering, Universiti Teknologi Malaysia (UTM), 81310 Johor Bahru, Johor, Malaysia

6. Faculty of Mechanical Engineering Technology, Pauh Putra Campus, Universiti Malaysia Perlis (UniMAP), 02600 Arau, Perlis, Malaysia

7. Faculty of Science and Technology, Department of Physics, Airlangga University, Surabaya, Indonesia

Abstract

A simple mirrorless plastic optical fiber displacement sensor was used to determine the concentration of paracetamol (PCM) in an aqueous solution. Paracetamol concentrations between 5 and 45 ppm were tested by the proposed sensor. With a mirror, the substantial sensitivity observed by an output power changed against displacement of 0.0403 mW/μm for the front slope and 0.023 mW/μm for the back slope with linearities of more than 99%. On the other hand, nonmirror reflector showed a sensitivity of 0.0006 mW/μm for the front slope and 0.0002 mW/μm for the back slope for the case of a red reflector and a sensitivity of 0.0007 mW/μm and 0.0003 mW/μm for the front and the back slope, respectively, for the case of a white reflector. The sensor sensitivity for the red and white coloured papers, which were used as the nonmirror reflectors and the mirror reflector itself against changing PCM concentrations, was 0.0004 mW/ppm, 0.0008 mW/ppm, and 0.02 mW/ppm, respectively. The experimental results indicated that the sensor was not only able to detect and measure the concentration of PCM in aqueous solutions but was also very stable with the additional advantages of a cost-effective and practical design that is highly beneficial for real-world sensing applications.

Funder

SPIE

Publisher

Hindawi Limited

Subject

Electrical and Electronic Engineering,Instrumentation,Control and Systems Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3