Critical Assessment of Single-Use Ureteroscopes in an In Vivo Porcine Model

Author:

Ceballos Brian1ORCID,Nottingham Charles U.1ORCID,Bechis Seth K.2ORCID,Sur Roger L.2ORCID,Matlaga Brian R.3,Krambeck Amy E.1

Affiliation:

1. Indiana University School of Medicine, Department of Urology, 1801 Senate Blvd. Suite 220, Indianapolis, IN 46202, USA

2. University of California San Diego School of Medicine, Department of Urology, 200 West Arbor Drive #8897, San Diego, CA 92103, USA

3. Johns Hopkins University School of Medicine, James Buchanan Brady Urological Institute, 600 North Wolfe Street Park 2 Room 221, Baltimore, MD 21287, USA

Abstract

Introduction and Objectives. In recent years, there has been increasing utilization of single-use ureteroscopes albeit with few studies comparing the performance characteristics between these devices. We compared two commonly utilized single-use ureteroscopes in a porcine model. Methods. A female pig was placed under general anesthesia and positioned supine, and retrograde access to the renal collecting system was obtained. The LithoVue (Boston Scientific) and Uscope (Pusen Medical) were evaluated by three experienced surgeons, and each surgeon started with a new scope. The following parameters were compared between each ureteroscope: time for navigation to upper and lower pole calyces with and without implements (1.9 F basket, 200 μm laser fiber, and 365 μm laser fiber for upper only) in the working channel and subjective evaluations of maneuverability, irrigant flow through the scope, lever force, ergonomics, and scope optics. Results. Navigation to the lower pole calyx was significantly faster with LithoVue compared to Uscope when the working channel was empty (24.3 vs. 49.4 seconds, p<0.01) and with a 200 μm fiber (63.6 vs. 94.4 seconds, p=0.04), but not with the 1.9 F basket. Navigation to the upper pole calyx was similar for all categories except faster with LithoVue containing the 365 μm fiber (67.1 vs. 99.7 seconds, p=0.02). Subjective assessments of scope maneuverability to upper and lower pole calyces when the scope was empty and with implements favored LithoVue in all categories, as did assessments of irrigant flow, illumination, image quality, and field of view. Both scopes had similar scores of lever force and ergonomics. Conclusions. In an in vivo porcine model, the type of single-use ureteroscope employed affected the navigation times and subjective assessments of maneuverability and visualization. In all cases, LithoVue provided either equivalent or superior metrics than Uscope. Further clinical studies are necessary to determine the implications of these findings.

Publisher

Hindawi Limited

Subject

Urology,Obstetrics and Gynecology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3