Clinical Implications of Oscillatory Lung Function during Methacholine Bronchoprovocation Testing of Preschool Children

Author:

Choi Sun Hee1,Sheen Youn Ho2,Kim Mi Ae3,Baek Ji Hyeon4,Baek Hey Sung5,Lee Seung Jin2,Yoon Jung Won6,Rha Yeong Ho1,Han Man Yong2ORCID

Affiliation:

1. Department of Pediatrics, Kyung Hee University School of Medicine, Seoul, Republic of Korea

2. Department of Pediatrics, CHA University School of Medicine, Seoul, Republic of Korea

3. Department of Medicines, CHA University School of Medicine, Seongnam, Republic of Korea

4. Department of Pediatrics, Dongtan Sacred Heart Hospital, College of Medicine, Hallym University, Hwaseong, Republic of Korea

5. Department of Pediatrics, Kangdong Sacred Heart Hospital, Hallym University, Seoul, Republic of Korea

6. Department of Pediatrics, Myongji Hospital, Seonam University College of Medicine, Goyang, Republic of Korea

Abstract

Objective.To investigate the repeatability and safety of measuring impulse oscillation system (IOS) parameters and the point of wheezing during bronchoprovocation testing of preschool children.Methods.Two sets of methacholine challenge were conducted in 36 asthma children. The test was discontinued if there was a significant change in reactance (Xrs5) and resistance (Rrs5) at 5 Hz (Condition 1) or respiratory distress due to airway obstruction (Condition 2). The repeatability of PC80_Xrs5, PC30_Rrs5, and wheezing (PCw) was assessed. The changes inZ-scores and SD-indexes from prebaseline (before testing) to postbaseline (after bronchodilator) were determined.Results.For PC30_Rrs5, PC80_Xrs5, and PCw for subjects, PC80_Xrs5 showed the highest repeatability. Fifteen of 70 tests met Condition2. The changes from pre- and postbaseline values varied significantly for Rrs5 and Xrs5. Excluding subjects withZ-scores higher than 2SD, we were able to detect 97.1% of bronchial hyperresponsiveness during methacholine challenge based on the change in Rrs5 or Xrs5. A change in IOS parameters was associated with wheezing at all frequencies.Conclusion. Xrs5 and Rrs5 have repeatability comparable with FEV1, and Xrs5 is more reliable than Rrs5. Clinicians can safely perform a challenge test by measuring the changes in Rrs5, Xrs5, andZ-scores from the prebaseline values.

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3