Long-Term Surgical Outcomes of Glaucoma Drainage Implants in Eyes with Preoperative Intraocular Pressure Less than 19 mmHg

Author:

Hallaj Shahin1ORCID,Wong Jae-Chiang1ORCID,Hock Lauren E.1,Kolomeyer Natasha Nayak1ORCID,Shukla Aakriti G.1ORCID,Pro Michael J.1,Moster Marlene R.1,Myers Jonathan S.1ORCID,Razeghinejad Reza1,Lee Daniel1

Affiliation:

1. Glaucoma Service, Wills Eye Hospital, Thomas Jefferson University, Philadelphia, PA 19107, USA

Abstract

Background. This retrospective review reports on patients who underwent glaucoma drainage implant (GDI) surgery and had baseline intraocular pressure (IOP) of ≤18 mmHg with at least one year of follow-up. Methods. Clinical data of 67 eyes of 67 patients were collected from patients’ charts, and the outcomes of GDI were evaluated until 7 years. GDI failure was defined as IOP reduction of less than 20% from the baseline at two consecutive visits three months after surgery, decline to no light perception, or if additional glaucoma surgery was performed. Results. The average age was 65.9 ± 13.2 years. Most cases were male (52.2%), White (53.7%), and had primary open-angle glaucoma (62.7%). Forty-four eyes had prior glaucoma surgery (68.6%) and 46 (68.6%) had severe glaucoma. Though postoperative (postop) IOP changes were insignificant, the average postop number of medications dropped from 2.4 ± 1.4 to 1.9 ± 1.2 medications two years after surgery (p=0.0451). Postop complications (23.9%) included GDI exposure (7.5%), inflammation (4.5%), shallow anterior chamber (4.5%), and strabismus (1.5%). Hypotony was observed in 4 eyes (5.9%), none of which developed hypotony maculopathy. The cumulative one-year failure rate was 56.7%, most of which were due to failure to lower IOP. Conclusion. In patients with baseline IOP ≤18 mmHg who had GDI surgery, though the change in IOP was not statistically significant, the number of medications dropped and visual field progression slowed in a subset of patients with adequate perimetric data. Due to a relatively high rate of complications and limited effectiveness in lowering IOP, GDI should be cautiously used in these eyes.

Funder

National Institutes of Health

Publisher

Hindawi Limited

Subject

Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3