The Functional Severity Assessment of Coronary Stenosis Using Coronary Computed Tomography Angiography-Based Myocardial Mass at Risk and Minimal Lumen Diameter

Author:

Sadamatsu Kenji1ORCID,Nagaoka Kazuhiro2,Koga Yasuaki3,Kagiyama Kotaro4,Muramatsu Kohei3,Hironaga Kiyoshi2,Tashiro Hideki1,Ueno Takafumi4,Fukumoto Yoshihiro4

Affiliation:

1. Department of Cardiology, St. Mary’s Hospital, Kurume, Japan

2. Department of Cardiovascular Medicine, Fukuoka City Hospital, Fukuoka, Japan

3. Department of Cardiovascular Medicine, Oita Prefectural Hospital, Oita, Japan

4. Division of Cardiovascular Medicine, Department of Internal Medicine, Kurume University School of Medicine, Kurume, Japan

Abstract

Background. We investigated whether or not the addition of myocardial mass at risk (MMAR) to quantitative coronary angiography was useful for diagnosing functionally significant coronary stenosis in the daily practice. Methods. We retrospectively enrolled 111 consecutive patients with 149 lesions who underwent clinically indicated coronary computed tomography angiography and subsequent elective coronary angiography with fractional flow reserve (FFR) measurement. MMAR was calculated using a workstation-based software program with ordinary thin slice images acquired for the computed tomography, and the minimal lumen diameter (MLD) and the diameter stenosis were measured with quantitative coronary angiography. Results. The MLD and MMAR were significantly correlated with the FFR, and the MMAR-to-MLD ratio (MMAR/MLD) showed a good correlation. The area under the receiver operating characteristic curve (AUC) of MMAR/MLD for FFR ≤ 0.8 was 0.746, and the sensitivity, specificity, positive predictive value, and negative predictive value were 60%, 83%, 68%, and 77%, respectively, at a cut-off value of 29.5 ml/mm. The addition of MMAR/MLD to diameter stenosis thus made it possible to further discriminate lesions with FFR ≤ 0.8 (AUC = 0.750). For the proximal left coronary artery lesions, in particular, MMAR/MLD showed a better correlation with the FFR, and the AUC of MMAR/MLD for FFR ≤ 0.8 was 0.919 at a cut-off value of 31.7 ml/mm. Conclusions. The index of MMAR/MLD correlated well with the physiological severity of coronary stenosis and showed good accuracy for detecting functional significance. The MMAR/MLD might be a useful parameter to consider when deciding the indication for revascularization.

Publisher

Hindawi Limited

Subject

Pharmacology (medical),Cardiology and Cardiovascular Medicine,Pharmacology,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3