Estimation of the Corneal Young’s ModulusIn VivoBased on a Fluid-Filled Spherical-Shell Model with Scheimpflug Imaging

Author:

Shih Po-Jen1,Huang Chun-Ju2,Huang Tzu-Han2,Lin Hung-Chou3,Yen Jia-Yush2ORCID,Wang I-Jong4ORCID,Cao Hui-Jyun2,Shih Wen-Pin2ORCID,Dai Chi-An5

Affiliation:

1. Department of Civil and Environmental Engineering, National University of Kaohsiung, Kaohsiung, Taiwan

2. Department of Mechanical Engineering, National Taiwan University, Taipei, Taiwan

3. Dr. Lin’s Eye Clinic and Laser Vision Correction Center, Taoyuan City, Taiwan

4. Department of Ophthalmology, College of Medicine, National Taiwan University, Taipei, Taiwan

5. Department of Chemical Engineering, National Taiwan University, Taipei, Taiwan

Abstract

Current intraocular pressure (IOP) measurement using air puff could be erroneous without applying proper corrections. Although noncontact tonometry is not considered to be accurate, it is still popularly used by eye clinics. It is thus necessary to extract the correct information from their results. This study proposes a practical approach to correctly measure IOPin vivo. By embedding a new model-based correction to the Corvis® ST, we can extract the corneal Young’s modulus from the patient data. This Young’s modulus can be used to correct the IOP readings. The tests were applied to 536 right eyes of 536 healthy subjects (228 male and 308 female) between March of 2012 and April of 2016. The tests were applied to patients at the Department of Ophthalmology, National Taiwan University Hospital and the Hung-Chuo Eye Clinics. The statistical analysis showed that the value for the Young’s modulus was independent of all the other parameters collected from the Corvis ST, including the corneal thickness and the intraocular pressure. Therefore, it is important to independently measure the Young’s modulus instead of depending on the correlation with the other parameters. This study adds the methodology of measuring corneal stiffnessin vivofor ophthalmologists’ reference in diagnosis.

Funder

Ministry of Science and Technology, Taiwan

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3