Laparoscopic vs. Robotic Gastrectomy in Patients with Situs Inversus Totalis: A Systematic Review

Author:

Multani Anmol1ORCID,Parmar Simran2ORCID,Dixon Elijah2ORCID

Affiliation:

1. Kansas City University – College of Medicine, Joplin, MO, USA

2. University of Calgary, Calgary, AB, Canada

Abstract

Background. Situs inversus totalis (SIT) is a rare genetic anomaly involving the mirror-image transposition of organs. This transposition can potentially make surgical treatments difficult because of the reversed anatomy and intraoperative confusion. The aim of this systematic review is to compare the perioperative outcomes and safety of robotic and laparoscopic gastrectomy in patients with SIT. Methods. We included full-text case reports with brief reviews and standalone case studies on SIT patients age ≥21, undergoing laparoscopic or robotic gastrectomy. We excluded case studies focusing on procedures other than laparoscopic and robotic gastrectomy, namely, open gastrectomy, gastric banding, and gastric bypass. English was selected as the language and articles published in the last 10 years were selected with a date range from Jan, 2011, to Aug, 2021. We focused on intraoperative and postoperative outcomes including blood loss, vascular aberrancy, operation duration, mortality, operative complications, duration of hospitalization, and follow-up interval. Online databases included Clinical Key, Embase, ScienceDirect, Ovid, and Google Scholar. The last search was conducted on Aug 15, 2021. For all eligible articles, risk of bias assessment was carried out using JBI critical appraisal checklist (Table 1). Continuous data were analyzed using t-test with p value of 0.05. Results. From our search, we retained 29 case reports which reported information from 30 cases. The results reported in each study were summarized (Table 2). The laparoscopic procedure was used in 21 cases and robot-assisted surgery was used in 9 cases. Operative time was mentioned in 24 out of the 30 cases and the average operative time was 205.67 min. Blood loss was reported in 16 out of the 30 cases, with an average blood loss of 51.9 mL. Hospital stay information was provided in 26 out of the 30 cases, with an average length of stay of 8.5 days. A statistically significant difference was not found for the operative time, length of hospitalization, or age of the patient. However, intraoperative blood loss in robot-assisted gastrectomy was lower compared to laparoscopic gastrectomy, with a p value of 0.0293. Perioperative death was not reported in any of the cases. Only three cases of postoperative complications were reported in laparoscopic surgery. Only one of the three cases suggested that the complication was due to an anomaly, whereas the other two of them reported complications due to procedural errors. Conclusion. Laparoscopic and robotic gastrectomy can be safely used for SIT patients if performed cautiously. Some precautions include thoroughly assessing anatomical aberrations using preoperative imaging, adjusting the operative set up, and having experienced surgeons. The robotic approach may have a few advantages over laparoscopic procedures that may enhance the surgical safety for SIT patients and need to be further explored in future research. Advantages of the robotic approach may include improved surgical safety with better visualization of the surgical field, promoting the stability of surgical instruments and perhaps allowing ease of surgical orientation and positioning when operating on patients with SIT. Further research in this field is merited.

Publisher

Hindawi Limited

Subject

Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3