Affiliation:
1. State Key Laboratory of Structural Analysis for Industrial Equipment, Department of Engineering Mechanics, Dalian University of Technology, Dalian 116024, China
Abstract
For a two-dimensional (2D) cellular-cored sandwich panel heat exchanger, there exists an optimum cell size to achieve the maximum heat transfer with the prescribed pressure drop when the length is fixed and the two plates are isothermal. However, in engineering design, it is difficult to find 2D cellular materials with the ideal cell size because the cell size selected must be from those commercially available, which are discrete, not continuous. In order to obtain the maximum heat dissipation, an innovative design scheme is proposed for the sandwich panel heat exchanger which is divided into multiple stages in the direction of fluid flow where the 2D cellular material in each stage has a specific cell size. An analytical model is presented to evaluate the thermal performance of the multistage sandwich panel heat exchanger when all 2D cellular materials have the same porosity. Also, a new parameter named equivalent cell size (ECS) is defined, which is dependent on the cell size and length of cellular material in all stages. Results show that the maximum heat dissipation design of the multistage sandwich panel heat exchanger can be converted to make the ECS equal to the optimal cell size of the single-stage exchanger.
Funder
National Natural Science Foundation of China
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献