Novel PEEK Retentive Elements versus Conventional Retentive Elements in Mandibular Overdentures: A Randomized Controlled Trial

Author:

Sharaf M. Y.1ORCID,Eskander Asharaf2,Afify Mohamed2

Affiliation:

1. Department of Prosthodontics, Faculty of Dentistry, University of Menoufia, Shibin Al Kawm, Egypt

2. Department of Prosthodontics, Faculty of Dentistry, University of Cairo, Cairo, Egypt

Abstract

Background. Many patients suffer from lack of retention of conventional mandibular overdentures due to loss of clip retention over time. Computer-aided design-computer-aided manufacturing (CAD-CAM) milled polyether ether ketone (PEEK) materials may be used for the construction of retentive housing and clips for improving retention of implant-supported overdentures. Objective. To compare retention and patient satisfaction of implant-supported mandibular overdentures retained by conventional nylon clip and metal housings for ball attachments versus PEEK clip and housings. Methods. Twenty-two participants were divided into 2 equal groups (n = 11). The conventional group received implant-supported mandibular overdentures retained by metal housings and nylon retentive elements, while the PEEK group received implant-supported mandibular overdentures retained by PEEK retentive elements and housings. The PEEK retentive elements were made using computer-aided design and computer-aided manufacturing (CAD-CAM). The evaluation included measuring the retention by applying a gradual pulling up force by force meter and patient satisfaction with a 7-point visual analog scale (VAS) at overdenture insertion and 3, 6, and 12 months subsequently by a research interviewer. Results. The PEEK group showed statistically significantly increased retention force ( P < 0.05 ) at the time of insertion (37.6/17.79) and after 3 months (33.9/16.78), 6 months (32.7/15.97), and 12 months (31.65/13.05). The conventional group had a statistically significantly higher mean overall satisfaction ( P < 0.05 ) at the time of insertion (65/82.18). No statistically significant difference was found after 3 months (87.81/84.72). The PEEK group showed statistically significantly higher mean overall satisfaction ( P < 0.05 ) after 6 months (86.36/80.18) and 12 months (85.45/79.54). Conclusions. According to the results of this study, the PEEK retentive material provided more retention than did the conventional material and led to improved patient satisfaction. The study was registered at clinical trials.gov (https://clinicaltrials.gov/ct2/show/NCT05079048).

Publisher

Hindawi Limited

Subject

General Dentistry

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3