Plasma Sterilization Effectively Reduces Bacterial Contamination in Dental Unit Waterlines

Author:

Noopan Sarocha1,Unchui Phattranit1,Techotinnakorn Supitcha1,Ampornaramveth Ruchanee Salingcarnboriboon1ORCID

Affiliation:

1. Research Unit on Oral Microbiology and Immunology, Department of Microbiology, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand

Abstract

Objective. To investigate the effectiveness of plasma sterilization in reducing bacterial contamination and controlling biofilms in dental unit waterlines.Materials and Methods. Ten identical dental chair units (DCUs) were used. Five DCUs were installed with an automated plasma sterilization system (PSS) and the other five were kept as nontreated controls (CTL). Water flushed from the airotor line served as the output water of the dental unit waterlines (DUWLs). Water samples were collected at the beginning and on a weekly basis for 4 months. Water was analyzed for bacterial contamination (CFU/mL). Scanning electron microscopy (SEM) was used to investigate the amount of biofilm in the waterlines. Biofilm viability was assessed by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) assays. All statistical analyses were performed using the Mann–WhitneyUtest. A value ofp<0.05was considered significant.Results. The DCU output water was found to be heavily contaminated with bacteria. Plasma sterilization effectively reduced bacterial contamination from an average of 212 CFU/mL to 8 CFU/mL. During the entire period of 4 months, the level remained below 500 CFU/mL, the standard level recommended by the Centers for Disease Control and Prevention (CDC) of the USA. The reduction in the bacterial count was significant compared with the CTL group (p<0.05). Plasma sterilization could not eradicate the existing biofilms in the waterlines, and it did reduce biofilm mass and viability. Moreover, treatment with plasma sterilization did not induce a change in the composition of microorganisms, as analyzed by Gram staining.Conclusion. Plasma sterilization, which is part of electrochemically activated water, effectively reduces bacterial contamination and reduces biofilms in dental unit waterlines.

Funder

Chulalongkorn University

Publisher

Hindawi Limited

Subject

General Dentistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3