Biomechanical Comparison and Three-Dimensional Analysis of Cement Distribution Patterns for Different Pedicle Screw Designs

Author:

Sung Sahyun12,Kwon Ji-Won1,Park Tae Hyun3,Lee Soo-Bin4,Moon Seong-Hwan1,Lee Byung Ho1ORCID

Affiliation:

1. Department of Orthopedic Surgery, Yonsei University College of Medicine, 03722 Seoul, Republic of Korea

2. Department of Orthopedic Surgery, Ewha Womans University College of Medicine, 07804 Seoul, Republic of Korea

3. School of Biomedical Engineering, Inje University, 50834 Gyeongnam, Republic of Korea

4. Department of Orthopedic Surgery, Catholic Kwandong University International Saint Mary's Hospital, 22711 Incheon, Republic of Korea

Abstract

The purpose of this study to explore strategies for reducing cement leakage during cement-augmented pedicle screw fixation, we compared the cement distribution patterns and biomechanical strengths of different types of cement-augmented fenestrated screws and traditional cement-augmented techniques. We compared five screw groups in this study: (1) Cannulated screws (Cann); (2) distal one-hole screws (D1); (3) distal two-hole screws (D2); (4) middle two-hole screws (M2); and (5) traditional screws with a traditional cement injection technique (Trad). The screws were inserted into cancellous bone blocks using a controlled, adequate cement injection pressure (1.6–2.0 kg), and an appropriate cement viscosity. Center to screw tip distance, three-dimensional distribution, and pull-out strength for cement were compared between groups. The average distance between the cement center and the screw tip was highest in the M2 group, suggesting a higher risk of cement leakage into the spinal canal. The Trad group had the highest migration distance in the z-axis, also reflecting a higher risk of leakage into the spinal canal. The D1 group had the highest pull-out strength ( 253 ± 48.82 N and 797 ± 58.31 N ) in bone blocks representing different degrees of osteoporosis, and the D2 group had the second highest pull-out strength in the severe osteoporosis model. Overall, D1 screws appeared to be the best option for optimizing biomechanical function and minimizing the risk of cement leakage into the spinal canal in patients with osteoporotic bone undergoing spinal surgery.

Funder

Ministry of Food and Drug Safety

Publisher

Hindawi Limited

Subject

General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3