Affiliation:
1. Università degli Studi dell'Insubria Department of Medicine and Surgery, Varese, Italy
2. UB-CARE S.r.l. Spin-Off University of Pavia, Pavia, Italy
3. Department of Medicine, College of Medicine and Health Sciences, UAE University, Al Ain, UAE
4. Università degli Studi di Pavia, Department of Molecular Medicine, Pavia, Italy
5. Università degli Studi della Campania “Luigi Vanvitelli”, Department of Maxillofacial Surgery, Napoli, Italy
6. Centro Medico Polispecialistico, Pavia, Italy
Abstract
During last years, hyaluronic acid- (HA-) based dermal fillers have grown rapidly and continuously, as reported by the American Society of Aesthetic Plastic Surgery (ASAPS). In fact, HA fillers are considered the gold standard technique for soft tissue augmentation, deep skin hydration, and facial recontouring, playing a key role as an alternative to plastic surgery. HA fillers are less invasive, more biocompatible, and safer and with a more natural and immediate result if compared to plastic surgery. Hence, the safety of HA-based dermal fillers plays a crucial role, mostly in terms of biocompatibility and adjustability in case of unpleasant results and side effects such as, tyndall effect, edema, or granulomas. Hyaluronidase is a naturally occurring enzyme, present in the human body, and can degrade HA fillers avoiding more severe complications. In this article, we analyzed the bioavailability of hyaluronidase degradation of five fillers of Neauvia® hydrogels line (MatexLab SA, Lugano, CH), composed of pure hyaluronic acid and based on PEGDE cross-linking (polyethylene glycol) technology that guarantees a higher biocompatibility and an optimal biointegration and rheological characteristics. The performedin vitrotesting is based on the colorimetric determination of the N-acetyl-D-glucosamine (NAG) present in solution after incubation with hyaluronidase, determined at different time points in order to assess the kinetic of each product degradation (1h, 3h, 6h, 24h, 48h, 72h, 120h, and 168h). The aim of this study was to assess,in vitro,how the difference in HA content and PEGDE concentration of the analyzed fillers can influence the product biocompatibility, intended as product enzymatic clearance and duration in time. The results demonstrated that the method was reproducible and easy to perform and that all the analyzed fillers are naturally immediately available for hyaluronidase-mediated degradation.
Subject
General Immunology and Microbiology,General Biochemistry, Genetics and Molecular Biology,General Medicine
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献