Development and Validation of a New Method for Determination of Pb and Cr in Marine Organisms by Total Reflection X-Ray Fluorescence (TXRF) Spectroscopy

Author:

Beltrán Blanca G.1ORCID,Martínez-Serrano Ibiza2ORCID,Ramos-Sanchez Victor3,Chávez-Flores David3ORCID,Nevárez-Rodríguez Myrna C.4ORCID,Suárez-Domínguez Emilio A.5ORCID

Affiliation:

1. Faculty of Nursing and Nutriology, Chihuahua Autonomous University, C.P. 31125 Chihuahua, Mexico

2. Museum of Zoology/Laboratory Hydrobiology, Faculty of Biology, Veracruzana University, C.P. 91090 Xalapa, Mexico

3. Faculty of Chemical Sciences, Chihuahua Autonomous University, C.P. 31125 Chihuahua, Mexico

4. Faculty of Agrotechnological Sciences, Chihuahua Autonomous University, C.P. 31125 Chihuahua, Mexico

5. Museum of Zoology, Faculty of Biology, Veracruzana University, C.P. 91090 Xalapa, Mexico

Abstract

Lead and chromium contamination represents one of the most serious problems in the aquatic environments. The aim of this work was to develop and validate an accurate, sensitivity, and rapid method for the simultaneous determination of Pb and Cr at trace levels in tissues and fat of marine organisms such as turtle (Chelonia mydas), shark (Rhizoprionodon terraenovae), and dolphin (Tursiops truncatus), utilizing the total reflection X-Ray fluorescence (TXRF) spectroscopy. Working solutions were prepared in 10 mL of a solution 0.005 mol·L−1 EDTA and 1 mol·L−1 HNO3. In order to correct possible instrument drifts, 20 μg·L−1 of gallium was used as internal standard (IS). The results showed that TXRF method was linear over the concentration ranges of 5.242–100 μg·L−1 for Pb and 2.363–100 μg·L−1 for Cr. Limits of detection (LOD) achieved were 1.573 and 0.709 μg·L−1 for Pb and Cr, respectively, while limits of quantification achieved were 5.242 μg·L−1 for Pb and 2.363 μg·L−1 for Cr. The validated method was accurate and precise enough for determination of these heavy metals in samples of marine organisms as indicated by acceptable values of recovery between 90–101%. In addition, a certified reference material (BCR-279, sea lettuce) and a Centrum tablet were satisfactory analyzed, and the T-test for comparison of means revealed that there were no significant differences at the 95% confidence level between the values obtained with the proposed TXRF method and the certificated values. The repeatability of the method, expressed as relative standard deviation (RSD), was 5.1% and 4%, for Pb and Cr, respectively. In addition, other features of the developed method were a low sample volume of 10 μL, and the sample frequency achieved was 20 h−1.

Funder

APIVER

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3