Determination of Isosorbide-5-Mononitrate in Human Plasma by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application to a Bioequivalence Study

Author:

Zhou Yinping1,Liu Aijing1,Jia Ranran1,Wu Mengyi1,Wu Ni1,Liu Chunyan1,Han Zhihui2,Hu Haitang2,Wang Hongyun1ORCID,He Qing3

Affiliation:

1. Clinical Pharmacology Research Center, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing Key Laboratory of Clinical PK and PD Investigation for Innovative Drugs, Beijing 100730, China

2. Livzon Group Medical Clinical Research Center, Zhuhai 519020, China

3. Wuxi People’s Hospital of Nanjing Medical University, Wuxi 214023, China

Abstract

Isosorbide-5-mononitrate (5-ISMN), an organic nitrate vasodilator, has been widely used worldwide to prevent angina pectoris for more than two decades. A simple and sensitive high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed and validated for the determination of 5-ISMN in human plasma. 13C6-5-ISMN is an internal standard, and 5-ISMN was extracted from human plasma (50 µL) with ethyl acetate (200 µL) by a simple liquid-liquid extraction method. The chromatographic separation was carried out on LC-20A (Shimadzu, Japan) using an analytical column ZORBAX XDB-C18 (4.6 × 50 mm, 5 µm), coupled with API 4000 tandem mass spectrometers in a multiple reaction monitoring (MRM) mode. The mobile phase was composed of acetonitrile (organic phase A) and 2 mM ammonium acetate in water (aqueous phase B) with an isocratic elution of A/B = 90 : 10 (v/v). The total run time was 3.5 min with a small injection volume (5 µL). This method was fully validated in every aspect of selectivity, linearity, accuracy, precision, matrix effect, extraction recovery, and different stabilities. It was proved that the calibration standards within the 5.00–1000 ng/mL concentration range were linear. The lower limit of quantification was 5.00 ng/mL for 5-ISMN. The intrabatch and interbatch accuracy (RE) ranged from −8.8% to 7.1% with precision between 2.4% and 6.6%. The mean values of 5-ISMN extraction recovery and matrix effect were 87.0% and 102.0%, respectively. The fully validated method was successfully applied for a bioequivalence clinical trial of oral 20 mg 5-ISMN tablets in healthy Chinese subjects.

Funder

Chinese National Major Project for New Drug Innovation

Publisher

Hindawi Limited

Subject

Computer Science Applications,Instrumentation,General Chemical Engineering,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3