Adequacy of Hemodialysis and Its Associated Factors among Patients Undergoing Chronic Hemodialysis in Dar es Salaam, Tanzania

Author:

Somji Samina S.1ORCID,Ruggajo Pascal1,Moledina Sibtain1ORCID

Affiliation:

1. Department of Internal Medicine, Muhimbili University of Health and Allied Sciences, P.O. Box 65001, Dar es Salaam, Tanzania

Abstract

The worldwide prevalence of maintenance hemodialysis continues to rise. An adequate delivery of hemodialysis dose as measured by Kt/V or urea reduction ratio is a crucial determinant of clinical outcome for chronic hemodialysis patients. The aim of this study was to assess the adequacy of hemodialysis and its associated factors among patients undergoing chronic hemodialysis in Dar es Salaam. This was a cross-sectional study done on patients undergoing chronic hemodialysis in four dialysis centers in Dar es Salaam. Sociodemographic information and treatment characteristics were collected. Urea reduction rate and single-pool Kt/V were calculated to determine the adequacy of hemodialysis. The data were analyzed and any associated factors for inadequate hemodialysis were determined using a chi-square test and a logistic regression analysis. A total of 143 patients participated in the study. Males represented 65.7% of the study population. The mean age (±SD) was 51.7 ± 1.2 years. Only 34.3% (based on urea reduction ratio (URR)) and 40.6% (based on Kt/V) of patients received adequate hemodialysis. The univariate analysis showed that males were more likely to have inadequate dialysis (65.6% versus 48.0%, p=0.048 based on Kt/V). Patients using hemodialyzers with dialyzer surface area less than 1.4 m2 received significantly less hemodialysis dose than those with more than 1.4 m2 (69.0% versus 41.2%, p=0.02, by URR) (62.7% versus 35.3%, p=0.03, by Kt/V criteria). Patients who had hemoglobin <10 g/dl received significantly inadequate hemodialysis dose as compared to patients with hemoglobin ≥10 g/dl by Kt/V criteria (69.8% versus 51.3%, p=0.03). None of the factors acquired significance in the multivariate analysis. The proportion of patients receiving an adequate hemodialysis dose is low (34.3% based on URR and 40.6% based on Kt/V). Male gender, dialyzer surface area of <1.4 m2, and hemoglobin level of <10 g/dl were associated with an inadequate delivered dose of hemodialysis in the univariate analysis but not in the multivariate analysis. This study can increase awareness about the importance of measuring hemodialysis adequacy and giving the correct hemodialysis dose to achieve the intended benefit.

Publisher

Hindawi Limited

Subject

Nephrology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3