Aim. Within the clinical setting, some patients have been identified as lacking in response to PGAs. This meta-analysis study aimed to evaluate the responsiveness of latanoprost, travoprost, bimatoprost, and tafluprost in OAG/OHT patients, latanoprost nonresponders (LNRs), and the IOP-reducing efficacy and safety. Methods. A literature search was conducted on PubMed, Embase, and the Cochrane Controlled Trials Register. The primary clinical endpoint was the number of responders at the end of the study. The secondary clinical endpoint was the IOP reduction at the endpoint from baseline. Safety evaluation included five common adverse events: conjunctival hyperemia, hypertrichosis, ocular burning, ocular itching, and foreign-body sensation. Results. Eleven articles containing ten RCTs were included in this meta-analysis study. The results highlighted that, in the OAG/OHT population, there was no statistically significant difference in the responsiveness of the four PGAs. Bimatoprost had a better IOP-reducing efficacy than latanoprost. There was no significant difference in the IOP-reducing efficacy of travoprost, latanoprost, and tafluprost. In LNRs, the responsiveness of bimatoprost, travoprost, and latanoprost did not show statistical differences. Bimatoprost reduced IOP with a greater extent than latanoprost and travoprost in LNRs, while there was no significant difference in the IOP-reducing efficacy of travoprost and latanoprost. No serious adverse events occurred with the treatment of the four PGAs. The prevalence of conjunctival hyperemia due to bimatoprost or tafluprost was significantly higher than that of latanoprost. Other adverse events had no significant difference between the four drugs. Conclusion. The existing studies cannot prove that latanoprost, travoprost, bimatoprost, and tafluprost have different responsiveness in OAG/OHT patients. Switching to bimatoprost or travoprost cannot achieve a significant improvement in responsiveness in LNRs. Bimatoprost has a better IOP-reducing efficacy than latanoprost and travoprost. No serious adverse events occurred during treatment with any medication we studied.

Funder

National Natural Science Foundation of China

Publisher

Hindawi Limited

Subject

Ophthalmology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3