Four-Channels High-Resolution Frequency Counter for QCM Sensor Array Using Generic FPGA XC6SLX9 Board

Author:

Triqadafi Adin O.1ORCID,Zafirah Tyas N.1ORCID,Dharmawan Hari A.2ORCID,Sakti Setyawan P.1ORCID

Affiliation:

1. Sensor Technology Laboratory, Department of Physics, Brawijaya University, Jl Veteran, 65145 Malang, Indonesia

2. Electronic Laboratory, Department of Physics, Brawijaya University, Jl Veteran, 65145 Malang, Indonesia

Abstract

A frequency counter is essential for resonance-based sensors like quartz crystal microbalance. An electronic nose or tongue using a QCM sensor array requires a multichannel frequency counter to detect the frequency shift of the sensors simultaneously. The frequency counter’s resolution, precision, and sampling speed are important factors. Board size, energy consumption, and rapid deployment are also considered in the design. This work shows the development of an independent multichannel frequency counter using a commercial Xilinx Spartan 6 series XC6SLX9 board module and a microcontroller board. Both modules are general-purpose modules; therefore, there is no need for a printed circuit board design, resulting in a quick implementation: the use of FPGA results in a compact size and low energy consumption. The developed counter is designed based on a reciprocal counter utilizing the internal logic block of the FPGA. The FPGA module has a built-in 50 MHz TCXO clock and is the reference clock. The high-resolution timing of the counter is realized by multiplying the 50 MHz clock by 6 to reach 300 MHz. The multiplication utilizes the PLL modules in the FPGA. The high precision and accuracy of the counter are achieved by calibrating the timing clock to a 10 MHz rubidium oscillator. The data communication to the microcontroller is done via the SPI by implementing the SPI protocol in the FPGA. The resource is optimized by utilizing PLL and DSP blocks for the counter. Only 5% registers and 5% LUTs of the FPGA resource are used to build a four-channel frequency counter. The result shows that the counter can measure the frequency of incoming signals with a resolution of 0.033 Hz at 10 MHz with a sampling time of 1 second. The system has been tested to monitor the frequency changes of a QCM sensor array.

Funder

Kementerian Riset dan Teknologi /Badan Riset dan Inovasi Nasional

Publisher

Hindawi Limited

Subject

Electrical and Electronic Engineering,General Computer Science,Signal Processing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3