Appropriate Use of Transesophageal Echocardiogram for Infective Endocarditis: A Single Center Experience

Author:

Singh Robby1ORCID,Naidu Moumita1,Bader Yousef1,Freeman David1,Zughaib Marcel1ORCID

Affiliation:

1. Providence Hospital, Michigan State University, Department of Cardiology, 16001 W Nine Mile Rd., Southfield, East Lansing, MI 48075, USA

Abstract

Background. Transesophageal echocardiogram (TEE) is a valuable tool in healthcare today with its ease of use, ability to visualize important structures not seen on transthoracic echocardiogram (TTE), and the relatively lower cost of TEE, high yield, and no significant radiation exposure. The American Society of Echocardiography (ASE) has developed an appropriate use criteria for use of TTE and TEE, which outline various scenarios where a TEE is indicated as an initial diagnostic testing modality and when it is useful as an adjunctive test in hopes of decreasing inappropriate use. Using these criteria as a guide, we devised a quality assessment study to investigate how well TEEs performed at our institution fit the appropriate use criteria specifically for the diagnostic workup of infective endocarditis. Methods. A retrospective chart review was performed for all TEEs performed in 2017 with the indication of endocarditis. Baseline patient characteristics, presence of bacteremia, and the quality of the TTE preceding the TEE were noted, as well as whether a vegetation, abscess, or perforation was visualized. We also determined if there was a cardiology consultation placed prior to TEE and if the patient had met the definition for endocarditis as defined by the Duke criteria. Finally, we made note of the TEE findings and assessed whether the TEE met appropriate use criteria developed by the American Society of Echocardiography. Results. A total of 50 patients who underwent TEE with the indication of “endocarditis” were identified. 36% of the TTEs prior to the TEE were rated as good quality, 40% as adequate, 4% as fair, 4% as suboptimal, 12% as technically difficult, and 4% were not rated. Vegetations were visualized on 12% of TTEs, 6% of patients had a prosthetic valve, and 6% had a cardiac device. In 20% of the cases, there was no cardiology consultation prior to the TEE and in 20% of the cases, there was no documented bacteremia. 26% of patients met the Duke criteria for endocarditis prior to TEE. Only 36% of TEEs revealed evidence of infection and of the patients with no evidence of infection, only 38% met appropriate use criteria. Overall, only 56% of patients met appropriate use criteria for TEE. Conclusion. Transesophageal echocardiography is a valuable tool in a modern physician’s arsenal for managing a variety of diseases and conditions. However, the procedure is not without associated risks and its ease of use and widespread adoption has led to frequent questionable appropriateness of use of the test. Only 56% of the TEEs performed in our analysis met appropriate use. More awareness and education is needed for the appropriate use criteria for transesophageal echocardiography as outlined by the ASE to help reduce patient exposure to procedure related complications and to decrease medical costs on unnecessary procedures.

Publisher

Hindawi Limited

Subject

Cardiology and Cardiovascular Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3