Abstract
This study focuses on the utilization of hydraulic accumulators to mitigate hydraulic shock. The pressure energy within the system is converted into compressed gas energy in the accumulator. This continuous conversion between the two forms of energy allows for the absorption of hydraulic shock force, thereby ensuring system stability. The study involved the creation of experimental circuits, which were tested both with and without the inclusion of a hydraulic accumulator. The results confirmed that the accumulator has a substantial impact on reducing hydraulic shock phenomena. The study's findings demonstrate that the shocks in the hydraulic system can be efficiently managed by selecting an appropriate inflation pressure for the accumulator and utilizing various connection line data.
Publisher
Publishing Center Science and Practice