Conventional videolaryngoscope versus 3D printed videolaryngoscope

Author:

Erel Kamil Varlık1ORCID,Ümit Karacan Nagehan2ORCID

Affiliation:

1. Department of Anesthesiology and Reanimation, Faculty of Medicine, Aydin Adnan Menderes University, Aydin, Turkey

2. Department of Anesthesiology and Reanimation, Faculty of Medicine, Karabuk University Research and Training Hospital, Karabük, Turkey

Abstract

<b>Background and objectives:</b> In patients with Covid-19, using a video laryngoscope as an alternative to direct laryngoscopy is recommended to protect the intubator from infection and reduce intubation failures due to personal protective equipment. The cost of video laryngoscopes limits their availability in all healthcare institutions. The present study aimed to compare the efficacy and safety of 3D printed video laryngoscope and conventional video laryngoscope on intubation.<br /> <b>Material and methods:</b> 30 ASA I-II patients who were not considered to have a difficult airway were included in the study after obtaining the ethics committee approval from Adnan Menderes University Clinical Research Ethics Committee. Patients were randomly divided into two groups, group 1 and group 2. After the induction of anesthesia under standard monitoring, the Cormack Lehane score was recorded by direct laryngoscopy in all patients. Patients in group 1 were intubated with a 3D-printed video laryngoscope. In contrast, patients in group 2 were intubated with a conventional video laryngoscope (STORZ C-mac videolaryngoscope). Intubation time, number of attempts, and hemodynamic values of patients with early postoperative complications were recorded. The data were recorded and statistically evaluated.<br /> <b>Results:</b> There were no significant differences between the groups regarding demographic data, BMI, and hemodynamic data. The Cormack Lehane score was calculated as 1.6±0.51 in group 1 and 1.4±0.51 in group 2 (p=0.38). Intubation times of the groups were 32.6±18 s and 27.06±11.37 s, respectively (p=0.4). The number of intubation attempts was 1.2±0.63 in group 1 and 1±0.01 in group 2 (p=0.31). The image quality of the camera by the intubator, intubation conditions, and intubation satisfaction was similar in the two groups.<br /> <b>Conclusion:</b><b> </b>Comparing a 3D-printed videolaryngoscope with a conventional videolaryngoscope, no differences were observed in intubation times, number of intubation attempts, hemodynamic changes, and early postoperative complications. Intubation satisfaction values by the practitioner were found to be similar. It was concluded that the 3D-printed videolaryngoscope, which is cost-effective and easy to access, can be used instead of conventional videolaryngoscope in patients with a normal airway.

Publisher

JSC National Scientific Medical Research Center

Subject

Industrial and Manufacturing Engineering

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3