Functionally Tailored Electro-Sensitive Poly(Acrylamide)-g-Pectin Copolymer Hydrogel for Transdermal Drug Delivery Application: Synthesis, Characterization, In-vitro and Ex-vivo Evaluation

Author:

Patil Sudha B.1,Inamdar Syed Z.1ORCID,Reddy Kakarla R.2,Raghu Anjanapura V.3ORCID,Akamanchi Krishnamachari G.4ORCID,Inamadar Arun C.5ORCID,Das Kusal K.6ORCID,Kulkarni Raghavendra V.1

Affiliation:

1. Department of Pharmaceutics, BLDEA’s SSM College of Pharmacy and Research Centre, Vijayapur 586 103, Karnataka, India

2. School of Chemical and Biomolecular Engineering, The University of Sydney, Sydney, NSW 2006, Australia

3. Department of Basic Sciences, School of Engineering & Technology, JAIN (Deemed-to-be University), Bangalore 562112, Karnataka, India

4. Department of Allied Health Sciences, Shri. B.M. Patil Medical College, Hospital & Research Centre, BLDE (Deemed to be University), Vijayapur 586 103, India

5. Department of Dermatology, Shri. B.M. Patil Medical College, Hospital & Research Centre, BLDE (Deemed to be University), Vijayapur 586 103, India

6. Department of Physiology, Shri. B.M. Patil Medical College, Hospital & Research Centre, BLDE (Deemed to be University), Vijayapur 586 103, India

Abstract

Background and Objectives: To develop electro-sensitive transdermal drug delivery systems (ETDDS) using polyacrylamide-grafted-pectin (PAAm-g-PCT) copolymer hydrogel for rivastigmine delivery. Methods: Free radical polymerization and alkaline hydrolysis technique was employed to synthesize PAAm-g-PCT copolymer hydrogel. The PAAm-g-PCT copolymeric hydrogel was used as a reservoir and cross-linked blend films of PCT and poly(vinyl alcohol) as rate-controlling membranes (RCMs) to prepare ETDDS. Results: The pH of the hydrogel reservoir was found to be in the range of 6.81 to 6.93 and drug content was 89.05 to 96.29%. The thickness of RCMs was in the range of 51 to 99 μ and RCMs showed permeability behavior against water vapors. There was a reduction in the water vapor transmission rate as the glutaraldehyde (GA) concentration was increased. The drug permeation rate from the ETDDS was enhanced under the influence of electric stimulus against the absence of an electric stimulus. The increase in flux by 1.5 fold was recorded with applied electric stimulus. The reduction in drug permeability observed when the concentration of GA was increased. Whereas, the permeability of the drug was augmented as an electric current was changed from 2 to 8 mA. The pulsatile drug release under “on– off” cycle of electric stimulus witnessed a faster drug release under ‘on’ condition and it was slow under ‘off’ condition. The alteration in skin composition after electrical stimulation was confirmed through histopathology studies. Conclusion: The PAAm-g-PCT copolymer hydrogel is a useful carrier for transdermal drug delivery activated by an electric signal to provide on-demand release of rivastigmine.

Publisher

Bentham Science Publishers Ltd.

Subject

Pharmacology, Toxicology and Pharmaceutics (miscellaneous),Pharmaceutical Science,Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3