Synchronized Assessment of Lobeglitazone Sulfate and Metformin Hydrochloride in Tablet by Robust, High-performance Thin-layer Chromatographic Method

Author:

Sen Dhanya B.1ORCID,Baldha Krunal1,Sen Ashim K.1ORCID,Maheshwari Rajesh A.1ORCID,Zanwar Aarti S.1ORCID,K. P. Greeshma2ORCID,Pradhan Prasanna K.3ORCID

Affiliation:

1. Department of Pharmacy, Sumandeep Vidyapeeth Deemed to be University, Piparia, Vadodara-391760, Gujarat, India

2. Department of Chemistry, Sri Ramakrishna College of Arts and Science (SRCAS), Coimbatore, 641006, Tamil Nadu, India

3. Pioneer Pharmacy Degree College, Ajwa-Nimeta Road, N.H. - 8, Sayajipura Village, Vadodara-390019, Gujarat, India

Abstract

Background: A combination of fixed-doses containing 0.5 mg lobeglitazone sulfate and 500 mg metformin hydrochloride has demonstrated efficacy in enhancing glycemic control in diabetes. Aims: The projected work aimed to establish and validate a high-performance thin-layer chromatographic methodology for the quantification of both drugs in tablet formulations. Objectives: The task involves creating and validating a method in accordance with ICH guidelines to quantify two particular drugs in tablet formulations accurately. Methods: The high-performance thin-layer chromatographic analysis utilized aluminum plates layered with silica gel 60F254, and the solvent system consisted of acetonitrile, 1 M ammonium acetate (methanol), toluene, and triethyl amine (1.5:2.5:4:0.2 v/v/v/v), followed by densitometric scanning at 237 nm. Results: The methodology exhibited linearity in the range of 100-1500 ng/band for lobeglitazone sulfate and 1000-15000 ng/band for metformin hydrochloride, with correlation coefficients of 0.9991 and 0.9992, correspondingly. Exceptional sensitivity was observed, with detection limits of 8.17 ng/band for lobeglitazone sulfate and 271.34 ng/band for metformin hydrochloride, along with quantification limits of 24.75 ng/band for lobeglitazone sulfate and 822.24 ng/band for metformin hydrochloride. The method demonstrated precision (% relative standard deviation of peak area <2) and accuracy (recovery between 96 and 103%). Conclusion: The suggested methodology is fit for the concurrent quantification of both drugs in tablet formulations, making it applicable for routine quality control assessments in laboratories.

Publisher

Bentham Science Publishers Ltd.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3