Reproducibility of Facial Information in Three-Dimensional Reconstructed Head Images: An Exploratory Study

Author:

Uchida Tatsuya1,Kin Taichi1,Sato Katsuya1,Koike Tsukasa1,Kiyofuji Satoshi1,Takeda Yasuhiro1,Niwa Ryoko1,Saito Toki2,Takashima Ikumi3,Kawahara Takuya3,Miyawaki Satoru1,Oyama Hiroshi2,Saito Nobuhito1

Affiliation:

1. Department of Neurosurgery, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan

2. Department of Clinical Information Engineering, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan

3. Data Science Office, Clinical Research Promotion Center, The University of Tokyo Hospital, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8655, Japan

Abstract

Background: Facial information acquired via three-dimensional reconstruction of head computed tomography (CT) data may be considered personal information, which can be problematic for neuroimaging studies. However, no study has verified the relationship between slice thickness and face reproducibility. This study determined the relationship and match rate between image slice thickness and face detection accuracy of face-recognition software in facial reconstructed models. Methods: Head CT data of 60 cases comprising entire faces obtained under conditions of non-contrast and 1-mm slice thickness were resampled to obtain 2-10-mm slice-thickness data. Facial models, reconstructed by image thresholding, were acquired from the data. We performed face detection tests per slice thickness on the models and calculated the face detection rate. The reconstructed facial models created from 1-mm slice-thickness data and other slice thicknesses were used as training and test data, respectively. Match confidence scores were obtained via three programs, match rates were calculated per slice thickness, and generalized estimating equations were used to evaluate the match rate trend. Results: In general, the face detection rates for the 1-10-mm slice thicknesses were 100, 100, 98.3, 98.3, 95.0, 91.7, 86.7, 78.3, 68.3, and 61.7 %, respectively. The match rates for the 2-10-mm slice thicknesses were 100, 98.3, 98.3, 95.0, 85.0, 71.7, 53.3, 28.3, and 16.7 %, respectively. Conclusions: The reconstructed models tended to have higher match rates as the slice thickness decreased. Thus, thin-slice head CT imaging data may increase the possibility of the information becoming personally identifiable health information.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3