Affiliation:
1. Affiliated Hospital of Weifang Medical University, School of Clinical Medicine, Weifang Medical University, Weifang,
China
Abstract
Background:
Diffusion tensor imaging (DTI), a novel method of describing nerve structure, is a special form of magnetic resonance imaging (MRI). This new imaging method can be used to
locate the diseased nerve roots in lumbar disc herniation.
Objective:
The objective of this study is to compare patient outcomes between single-level and doublesection percutaneous endoscopic lumbar discectomy (PELD) in the treatment of lumbar intervertebral
disc herniation with single nerve root compression, where single-sided PELD is guided by magnetic
resonance diffusion tensor imaging (DTI).
Methods:
The clinical data of patients with lumbar intervertebral disc herniation with double compression of single nerve root symptoms in the Affiliated Hospital of Weifang Medical University from
January 2019 to May 2021 were retrospectively summarized and divided into single-level percutaneous endoscopic discectomy (PELD) group after DTI localization and double-section PELD group. The
operation time, intraoperative bleeding, VAS score and JOA score of the two groups were compared,
as well as the preoperative and postoperative fractional anisotropy (FA) values in the DTI group.
Results:
The operation time and intraoperative bleeding volume of patients in the DTI group were
significantly lower than those in the double segment group, and there was no significant difference
between VAS scores and JOA scores in the two groups. After the operation, the nerve root FA value of
the responsible compression site of patients in the DTI group increased significantly, but it was still
lower than the healthy symmetrical part.
Conclusion:
The single-level PELD based on DTI has achieved a similar effect to that of the doublesegment PELD in 3 months after the operation, which can improve the FA value of the lesion nerve
root. Its bleeding amount is less, and the operation time is shorter, but the efficacy of this technology
still requires long-term follow-up of large samples.
Funder
Weifang Science and Technology Bureau
Publisher
Bentham Science Publishers Ltd.
Subject
Radiology, Nuclear Medicine and imaging
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献