Parameters of Dual-layer Spectral Detector CT Could be Used to Differentiate Non-Small Cell Lung Cancer from Small Cell Lung Cancer

Author:

Zhu Xiqi1,Mu Ronghua2,Meng Zhuoni2,Zhang Xiaodi3,Guo Zixuan2,Zheng Wei2,Zhuang Zeyu2

Affiliation:

1. Department of Medical Imaging, Nanxishan Hospital of Guangxi Zhuang Autonomous Region, Guilin, 541004, China

2. Graduate School of Guilin Medical University, Guilin, 541004, China

3. Philips (China) Investment Co., Ltd. Chengdu Branch, 610000, China

Abstract

Background and Objective: Differentiating non-small cell lung cancer (NSCLC) from small cell lung cancer (SCLC) remains a substantial challenge. This study aimed at evaluating the performance of dual-layer spectral detector CT (DLCT) in differentiating NSCLC from SCLC. Methods: Spectral images of 247 cancer patients confirmed by pathology were retrospectively analyzed in both the arterial phase (AP) and the venous phase (VP), including 197 cases of NSCLC and 50 cases of SCLC. Effective atomic number (Z-eff), Spectral CT-Mono Energetic (MonoE [40keV~90keV]), iodine density (ID) and thoracic aorta iodine density (IDaorta) in contrast-enhanced images were measured and compared between the SCLC and NSCLC subgroups of tumors. The slope of the spectral curve (λ, interval of 10 keV) and normalized iodine density (NID) were also calculated between the SCLC and NSCLC. Through the statistical analysis, the diagnostic efficiency of each spectral parameter was calculated, and the difference in their efficiency was analyzed. Results: Both in NSCLS and SCLC, all parameters in VP were significantly higher than those in AP (p<0.001), except for λ90. There were significant differences in all spectral parameters between NSCLS and SCLC, both in AP and VP (p < 0.001). Except for VP-λ90, there was no significant difference in ROC curves of all spectral parameters. VP-NID exhibited the best diagnostic performance with an AUC value of 0.917 (95%[CI]: 0.870~0.965), sensitivity and specificity of 92.9% and 80%, and a diagnostic threshold of 0.217. Conclusion: All parameters of DLCT have high diagnostic efficiency in differentiating NSCLC from SCLC except for VP-λ90, and VP-NID has the highest diagnostic efficiency.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3