Conventional versus Aspiration-type Needles in CT-guided Biopsy for Chest Pathologies/Lesions: A Comparative Study

Author:

Fukushima Kenji1ORCID,Sekino Hirofumi1ORCID,Ishii Shiro1ORCID,Yamakuni Ryo1ORCID,Suenaga Hiroki1ORCID,Kuroiwa Daichi1ORCID,Ito Hiroshi1ORCID

Affiliation:

1. Department of Radiology and Nuclear Medicine, Fukushima Medical University, Fukushima, Japan

Abstract

Background: Larger sample volume can be obtained in one needle pass using an aspiration-type semi-automatic cutting biopsy needle (STARCUT® aspiration-type needle; TSK Laboratory, Tochigi, Japan) in comparison to the conventional semi-automatic cutting biopsy needle. Objective: To evaluate and compare the safety and effectiveness of aspiration-type semi-automatic cutting biopsy needles and non-aspiration-type biopsy needles when performing computed tomography (CT)-guided core needle biopsies (CNBs). Methods: A total of 106 patients underwent CT-guided CNB for chest lesions between June 2013 and March 2020 at our hospital. Non-aspiration-type cutting biopsy needles were used in 47 of these patients, while aspiration-type needles were used in the remaining 59 patients. All needles used were 18- or 20-gauge biopsy needles. Parameters, like forced expiratory volume in 1-second percent (FEV1.0%), the maximum size of the target lesion, puncture pathway distance in the lung, number of needle passes, procedure time, diagnostic accuracy, and incidence of complications, were measured. Comparisons were made between the needle-type groups. Results: No significant difference was observed in terms of diagnostic accuracy. However, the procedure time was shorter and a lesser number of needle passes were required with the aspiration-type cutting biopsy needle compared to the non-aspiration-type needle. Pneumothorax and pulmonary hemorrhage were the complications encountered, however, their incidence was not significantly different between the two types of needles. Conclusions: The aspiration-type semi-automatic cutting biopsy needle had similar diagnostic accuracy as the non-aspiration-type biopsy needle, with added advantages of a lesser number of needle passes and shorter procedure time.

Publisher

Bentham Science Publishers Ltd.

Subject

Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3