Author:
Singh Malik Krishan Pal,Goel Ruchi,Kishore Divya,Nagpal Smriti
Abstract
Single loop fixation of posterior chamber intraocular lens in the presence of partial capsular support is usually
performed by creation of additional scleral flap or tunnel. This extra port may expose the suture holding the intraocular
lens or the tucked-in lens haptics to the outside environment thereby increasing the risk of endophthalmitis. We describe a
technique of single loop fixation where the scleral tunnel is created adjacent to the site with the absent capsule, the leading
haptic is placed on the capsular scaffold, the trailing haptic is tied to 9-0 polypropylene, and the suture is then secured to
the inner edge of the scleral lip with enough tension to center the optics and the wound is then closed. The suture knot gets
buried within the scleral tunnel with no external communication and does not require a separate port. It is an easy, safe,
fast and reproducible technique with a lens tilt of less than 2°.
Publisher
Bentham Science Publishers Ltd.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献