A Validated Reverse-Phase High Performance Liquid Chromatography (RP-HPLC) Method for the Quantification of Gamma- Tocotrienol in Tocotrienol Rich Fractions of Crude Palm Oil

Author:

Nair Rajesh Sreedharan1ORCID,Billa Nashiru2ORCID,Morris Andrew3ORCID

Affiliation:

1. School of Pharmacy, The University of Nottingham Malaysia, Jalan Broga, 43500 Semenyih, Selangor Darul Ehsan, Malaysia | School of Pharmacy, Monash University Malaysia, Jalan Lagoon Selatan, 47500 Bandar Sunway, Selangor Darul Ehsan, Malaysia

2. College of Pharmacy, QU Health, Qatar University, Doha, Qatar | Biomedical and Pharmaceutical Research Unit (BPRU), QU Health, Qatar University, Doha, Qatar

3. School of Pharmacy, The University of Nottingham Malaysia, Jalan Broga, 43500 Semenyih, Selangor Darul Ehsan, Malaysia | Swansea University Medical School, Swansea University, Singleton Park, Swansea, UK

Abstract

Background: Palm oil and its constituents have wide applications in food, cosmetics and pharmaceutical industries. The tocotrienol-rich fractions of crude palm oil have drawn greater research interest in recent years due to their potent health benefits. Therefore, reliable and validated analytical methods are essential for the quantification of tocotrienols. Objective: This study aimed to develop a simple and economical RP-HPLC method for the quantification of gamma-tocotrienol in tocotrienol-rich fractions of crude palm oil. Methods: An Agilent HPLC system supplied with a Diode Array detector and an auto-injector system was used for the method development, and the wavelength was set 295 nm. A reversedphase C18 column maintained at 30 °C using a mobile phase composition of methanol: water (95:05) at a flow rate of 1 mL/min was used for the analysis. The developed method was validated according to ICH guidelines. Results and Discussion: A symmetrical peak of gamma-tocotrienol was observed at 8.7 minutes with minimal peak tailing (between 0.76 and 0.78), and an acceptable resolution above 2.0. Excellent linearity was evident with R2 values 0.9996 and 0.9991 for intra-day and interday, respectively. The method demonstrated a high precision (%RSD values ≤ 5.8%) and accuracy (%RE<9.6%). The LOD and LOQ of gamma-tocotrienol were determined as 1.4 μg/mL and 4.2 μg/mL, respectively. The system suitability studies indicate that the chromatographic parameters are well within the acceptable limit. Conclusion: In conclusion, the developed RP-HPLC method is rapid, precise, stable and economical for the quantification of gamma-tocotrienol.

Publisher

Bentham Science Publishers Ltd.

Subject

Public Health, Environmental and Occupational Health,Nutrition and Dietetics,Food Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3