Affiliation:
1. Department of Mechanical Engineering, University of Liverpool
Abstract
Four 250 mm (10 inch) equal diameter branch junctions of different thickness have been subjected to all six external moment loadings that can occur in practice, together with internal pressure in one case. The results of detailed experimental stress analyses are presented and are discussed in the light of current American and British piping design codes.
Cited by
19 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献