Compliant layer bearings in artificial joints. Part 1: The effects of different manufacturing techniques on the interface strength between an elastomeric layer and a rigid substrate

Author:

Burgess I C1,Jones E2,Scholes S C1,Unsworth A1

Affiliation:

1. Centre for Biomedical Engineering, Durham University, Durham, UK

2. Stryker Orthopaedics, Raheen Business Park, Limerick, Ireland

Abstract

The premise that elastomeric materials could be used as one or more of the articulating components in both hip and knee prostheses was postulated first by Unsworth and co-workers. It was thought that such materials might have the capacity to mimic natural joint behaviour more closely than the more rigid bearing surfaces commonly in use. A more natural joint function in artificial joints should promote better tribology, with full fluid-film lubrication being the goal. Early tests showed that this objective could potentially be achieved with a judicious choice of materials and carefully controlled manufacturing techniques. This paper (Part 1 of a two-part series) describes and explains the techniques used to verify the material selection as well as to determine the most appropriate manufacturing procedure to obtain a strong and robust interface between the support and bearing material of the prosthesis. Two polycarbonate urethane (PU) materials with different hardness values (Corethane 80A and Corethane 75D) gave sufficient interfacial strength when moulded under optimum conditions. Corethane 80A was used as the soft bearing material while Corethane 75D provided the rigid backing component. Peel tests revealed strong interface bonds, varying with processing conditions between 350 and 862 N. Fourier transform infrared spectroscopy and micro-thermal analysis showed that a fusion bond over 30 μm thick formed at the interface. The results of the range of tests and analyses, which have been used in this study, have provided sufficient evidence to validate the process used to manufacture these components.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Retrieval analysis of a failed TriboFit polycarbonate urethane acetabular buffer;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2016-02-01

2. Evaluation of the wear performance of a polycarbonate-urethane acetabular component in a hip joint simulator and comparison with UHMWPE and cross-linked UHMWPE;Journal of Biomaterials Applications;2011-02-22

3. Compliant layer knee bearings;Wear;2010-07

4. In-vitro evaluation of a polyurethane compliant-layer glenoid for use in shoulder arthroplasty;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2009-11-13

5. Compliant layer bearings in artificial joints. Part 2: Simulator and fatigue testing to assess the durability of the interface between an elastomeric layer and a rigid substrate;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2008-12-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3