Charnley wear model for validation of hip simulators' ball diameter versus polytetrafluoroethylene and polyethylene wear

Author:

Clarke I C1,Good V1,Anissian L2,Gustafson A2

Affiliation:

1. Loma Linda University Medical Center Howard and Irene Peterson Tribology Laboratory Loma Linda, California, United States of America

2. Loma Linda University Medical Center Department of Orthopedics Loma Linda, California, United States of America

Abstract

Wear rates of polytetrafluoroethylene (PTFE) and polyethylene cups were compared in 9-channel and 12-channel simulators, using serum lubrication and gravimetric techniques for wear assessment. Cobalt-chromium (CoCr) and alumina ceramic femoral heads in 22-42 mm diameter range were used to validate simulator wear rates against clinical data. This was also the first study of three femoral head sizes evaluated concurrently in a simulator (with three replicate specimens) and also the first report in which any wear experiments were repeated. Fluid absorption artefacts were within ± 1 per cent of wear magnitude for PTFE and ± 8 per cent for polyethylene and were corrected for. Wear rates were linear as a function of test duration. Precision within each set of three cups was within ±6 per cent. The wear rates from experiments repeated over 15 months were reproducible to within ± 24 per cent. However, the magnitudes of the simulator wear rates were not clinically accurate, the PTFE wear rates (2843 mm3/106cycles; 22 mm diameter) were over three times higher than in vivo, the polyethylene 30 to 50 per cent on the low side (23 mm3/106cycles; 22 mm diameter). Volumetric wear rate increased with respect to size of femoral head and a linearly increasing relationship of 7-8 per cent/mm was evident with respect to femoral head diameter for both PTFE and polyethylene. These data compared well with the clinical data.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 62 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Biotribology;Joint Replacement in the Human Body;2024

2. Hip joint replacements;Joint Replacement in the Human Body;2024

3. Testing the efficiency of Bronze Age axes: An interdisciplinary experiment;Journal of Archaeological Science;2023-04

4. Engineering of a multi-station shoulder simulator;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2016-05

5. Tribology of UHMWPE in the Hip;UHMWPE Biomaterials Handbook;2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3