Comparative evaluation of linear dimensional accuracy of impressions made with different elastomeric impression materials (Polyether and Polyvinyl siloxane) in angulated and parallel implants-An invitro study

Author:

Paul Nirupam1,Barman Jogeswar2,Goswami Barasha

Affiliation:

1. Agartala Government Medical College and Govind Ballabh Pant Hospital, Agartala, Tripura, India

2. A

Abstract

To date no technique has been proven to guarantee a completely passive fit of implant supported prosthesis framework. Several clinical variables such as angulation of implants, impression material and technique used may affect the precision of impressions. Hence, this study is designed to evaluate and compare the dimensional accuracy of the resultant casts made from open tray implant level impressions with two different impression materials (polyvinyl siloxane and polyether) in parallel and angulated implants. The study consisted of two control groups; master model –1with parallel implants and master model –2 with angulated implants. From master model 1and master model 2, total 40 implant level open tray impressions were made using PVS and polyether impression material and impressions were poured to obtain 40 study casts. The resultant casts were divided into 4 groups (10 casts in each group), according to the impression material used (PVS or Polyether) and implant’s orientation (parallel or angulated) in the casts. All casts were evaluated for the positional accuracy of the implant by using four reference distances with the help of a profile projector. These measurements were compared to the measurements calculated on the master model, which served as a control. The variations of the mean distance values with respective control values within a group were analyzed with one samples’ t’ test at 0.05 significance level. Further the mean distance variations between the groups were analyzed with independent samples ‘t’ test to evaluate group mean variations.The impressions made in the presence of angulated implants were significantly less accurate than the ones made with parallel implants. Regarding impression material the tested polyether resulted advantageous over polivinylsiloxane impression material in terms of recording positional accuracy of implants.

Publisher

IP Innovative Publication Pvt Ltd

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3